Digital In / Out - Danfoss VLT AQUA Drive FC 200 Instruction Manual

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

VLT AQUA Low Harmonic Drive Instruction
Manual

6.4.7 5-** Digital In / Out

Par.
Parameter description
No. #
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
5-17
Terminal X30/3 Digital Input
5-18
Terminal X30/4 Digital Input
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 digital Output
5-32
Term X30/6 Digi Out (MCB 101)
5-33
Term X30/7 Digi Out (MCB 101)
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-54
Pulse Filter Time Constant #29
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-59
Pulse Filter Time Constant #33
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
5-62
Pulse Output Max Freq #27
5-63
Terminal 29 Pulse Output Variable
5-65
Pulse Output Max Freq #29
5-66
Terminal X30/6 Pulse Output Variable
5-68
Pulse Output Max Freq #X30/6
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
5-93
Pulse Out #27 Bus Control
5-94
Pulse Out #27 Timeout Preset
5-95
Pulse Out #29 Bus Control
5-96
Pulse Out #29 Timeout Preset
5-97
Pulse Out #X30/6 Bus Control
5-98
Pulse Out #X30/6 Timeout Preset
Default value
(SR = Size related)
[0] PNP - Active at 24 V
[0] Input
[0] Input
[8] Start
[0] No operation
null
[14] Jog
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
null
0.01 s
0.01 s
100 Hz
100 Hz
0.000 N/A
100.000 N/A
100 ms
100 Hz
100 Hz
0.000 N/A
100.000 N/A
100 ms
[0] No operation
5000 Hz
[0] No operation
5000 Hz
[0] No operation
5000 Hz
0 N/A
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
®
MG.20.T1.22 - VLT
is a registered Danfoss trademark
6 How to Program the Low Harmonic Drive
4 set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
6
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint32
-2
N2
-2
Uint16
-2
N2
-2
Uint16
-2
N2
-2
Uint16
6-53

Advertisement

Table of Contents
loading

Table of Contents