Parameter Function
Channel
PTZ Type
Protocol
Address
Baud
Rate
Data Bit
Stop bit
Parity
4.11.5.5 POS
Connect the NVR to the POS, it can receive the POS information and overlay on the corresponding
record.
Note
POS info overlay and playback function is for 1-window only.
From main menu->Setting->System->POS, you can go to the following interface. See Figure 4-127.
Click Add, you can see the following dialogue box. See Figure 4-128.
Figure 4-126
Select speed dome connected channel.
There are two options: local/remote.
Please select remote type if you are connecting to the network PTZ.
Please select local type if you are using RS485 to the PTZ camera.
Select the corresponding dome protocol such as PELCOD.
Set corresponding dome address. Default value is 1. Please note
your setup here shall comply with your dome address; otherwise
you cannot control the speed dome.
Select the dome baud rate. Default setup is 9600.
The value ranges from 5 to 8. Default setup is 8. Please set according
to the speed dome dial switch setup.
The value ranges from 1 to 2. Default setup is 1. Please set according
to the speed dome dial switch setup.
The options include non/odd/even/space/null. Default setup is none.
Please set according to the speed dome dial switch setup.