Nearloop - Polycom HDX series Reference Manual

Polycom hdx systems version 1.0
Hide thumbs Also See for HDX series:
Table of Contents

Advertisement

Integrator's Reference Manual for Polycom HDX Systems

nearloop

4 - 162
Activates or deactivates the Near End Loop test.
Syntax
nearloop <on|off>
Parameter
on
off
Feedback Examples
nearloop on
returns
nearloop on
cs: call[41] chan[0] dialstr[] state[ALLOCATED]
active: call[41] speed[384]
nearloop off
returns
nearloop off
cleared: call[41]
dialstring[IP: NAME:]
ended: call[41]
Comments
When Near End Loop is on, you can test the encoder/decoder on the system.
This can help you diagnose a problem with a video call. If you perform a near
end loop test during a call, the far site sees a loop of itself.
Description
Activates the Near End Loop, a complete internal test
of the system.
Deactivates the Near End Loop.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDX series and is the answer not in the manual?

Questions and answers

Table of Contents