A. Examples of the use of INFO A6 mode
Below are some examples with practical applications of the Info A6 mode.
A.1. INFO A6 mode with the machine connected to a smart external control unit
If the washing machine is connected to a smart external control unit (PLC or similar), the A6 Info mode will make
it possible to transfer the value of the load entered as well as a decimal code that activates a function of the
smart control unit.
For this case, the user needs to transfer a linen load value of 20 kg (44 lb) and the decimal code 8 in an HS-
6040 washer. To do so it is advisable to create the program 1 with two phases at the beginning of the washing
cycle which allow this information to be transferred as shown below:
Pr
1
Ph
1
0
0
0
2
0
0
0
3
2
3
40
4
2
2
65
5
2
4
30
6
1
5
0
7
1
5
0
8
2
4
0
Phase
Symbol
Value
1
5
Ph1
20
5
2
5
Ph2
8
5
Appendices to the manual
32
0
1
5
32
0
2
5
104
1
0
0
149
2
0
0
86
3
0
0
32
0
0
0
32
0
0
0
32
4
0
0
Description
Signal that notifies the smart control unit that the value transmitted from the
A6(I/O2) board will be the weight of the load.
Duration of the previous signal. Sufficient time should be programmed for the smart
control unit to be able to read it.
Weight of the load. On machines with a weight control system, the weight of the
load is automatically read by the washing machine's microprocessor, on machines
without a weight control system, it must be entered manually using the
alphanumeric keypad. In this case, 20kg (44lb). This value cannot be changed
while the program is running.
Duration of the previous signal. Sufficient time should be programmed for the smart
control unit to be able to read it.
Signal that notifies the smart control unit that the value transmitted from the
A6(I/O2) board will be the desired decimal number.
Duration of the previous signal. Sufficient time should be programmed for the
dosing control unit to be able to read it.
Decimal number to be transferred to the smart control unit.
Duration of the previous signal. Sufficient time should be programmed for the smart
control unit to be able to read it.
5
0
0
5
0
0
0
0
5
4
0
0
5
10
0
0
5
4
0
0
5
2
0
0
5
2
0
0
5
3
83
0
0
0
0
0
0
0
0
0
1
2
2
0
1
3
2
0
1
2
2
0
1
1
1
0
1
1
1
0
1
6
9