7.5.2. Typical uses of the INFO A6 mode for transferring a numerical value

There are two main uses for numerical value transfers:
Used to activate three or more dosings simultaneously.
With this selection it is possible to dose three or more products (up to a maximum of eight) in a single
washing phase using the outputs d5...d2...d5 of the A6(I/O2) board. The numerical value entered
represents the outputs of the A6(I/O2) board to be activated (see the output activation table for the
A6(I/O2) board in Section 7.5.3).
It is possible to have a total of up to ten dosing signals in the same phase:
: First dosing: 1 internal or external signal (A4 board).
: Second dosing: 1 internal or external signal (A4 board).
: Third dosing: up to 8 external signals (A6(I/O2) board.
The three dosing groups may have a different time between them, however, the dosings assigned in the
third dosings will have the same time and be equal to the value entered in the parameter:
Information time in Info A6 mode
Used to transfer a decimal number
Another application for this selection can occur on machines connected to an external smart control unit
(PLC or similar). With this option, using the Inteli control alphanumeric keypad, the user can enter a
decimal number such as the program number of an external dosing control unit.
Programming a new wash program
(see Section 7.3.8).
47
Code 429159
Rev. 15/0717