PROGRAMMED DURATION OF THE BUZZER
Modifies the number of acoustic beeps at the end of the phase (section 7.3.14).
The multi-function and numerical keyboard can be used interchangeably.
Programmable values ............... 0 – 20
Factory settings .......................... 2
PERMISSION OF ACCELERATION
Permits inhibiting the acceleration function described in section 4.4.
Programmable values .............. YES / NO
Factory settings ......................... YES
EXTERNAL BUZZER
Option available only in machines with A6 (I/O2) input and output board installed and activated in the SETUP
menu.
If the external buzzer is activated, the electrical circuit between terminals X4-5 and X4-6 of the A6(I/O2)
board closes when the machine beeps at the end of the cycle or due to an alarm. This option permits
monitoring the acoustic beeps to the outside of the machine.
It is a free voltage circuit. Maximum voltage: 240V AC. Maximum current: 1A.
Programmable values .............. YES / NO
Factory settings ......................... NO
DOSING TEMPERATURE CONTROL 2 (INTERNAL)
(Option only available in HS-6013, HS-6017; EH030 and EH040 models.)
The YES temperature control option at the second internal dosing 2 (factory settings) will supply this
dispenser compartment with a hot and cold water mixture depending on the temperature programmed at the
phase.
Programming the NO option at the second internal dosing 2 will supply this dosing department with cold
water.
Programmable values .............. YES / NO
Factory settings ......................... YES
LOAD DETECTION
Activates a weighing mode in accordance with the programmable value:
Programmable values .................
Factory settings ............................ AUTO
WEIGHING UNITS
This option only appears if the manual LOAD DETECTION option or that by loading cells has been activated.
Programmable values ..............
Factory settings ......................... KG.
PROPORTIONAL WATER LEVEL
This option only appears if the manual, automatic or loading cell LOAD DETECTION option has been
activated.
Modify the bath level values in proportion to the load selected and in accordance with the machine's limits.
Programmable values .............. YES / NO
Factory settings ......................... NO
System tools
NO
MANUAL: Programming the load manually using the keypad.
AUTO: Detecting the load automátically. Applies to Programs 1 to 95. This mode
is incompatible with Easy Load and Tilt systems to aid loading. (This mode does
not apply to HS-6024 and HS-6032 models).
CEL: Detection by loading cells. For this option to operate, the scales assembly
and weight display module need to be installed. (HS-6023, HS-6040, HS-6057
and HS-6110 models only).
KG: The weight of the load is in kg.
LB: The weight of the load is in lb.
59
Code 429159
Rev. 15/0717