Kubota L2800 Workshop Manual page 363

Hide thumbs Also See for L2800:
Table of Contents

Advertisement

L2800, L3400, WSM
Tractor Manuals Scotland
Battery Specific Gravity
1. Check the specific gravity of the electrolyte in each cell with a
hydrometer.
2. When the electrolyte temperature differs from that at which the
hydrometer was calibrated, correct the specific gravity reading
following the formula mentioned in (Reference).
3. If the specific gravity is less than 1.215 (after it is corrected for
temperature), charge or replace the battery.
4. If the specific gravity differs between any two cells by more than
0.05, replace the battery.
NOTE
• Hold the hydrometer tube vertical without removing it from
the electrolyte.
• Do not suck too much electrolyte into the tube.
• Allow the float to move freely and hold the hydrometer at eye
level.
• The hydrometer reading must be taken at the highest
electrolyte level.
(Reference)
• Specific gravity slightly varies with temperature. To be exact, the
specific gravity decreases by 0.0007 with an increase of
1 °C (0.0004 with an increase of 1 °F) in temperature, and
increases by 0.0007 with a decreases of 1 °C (0.0004 with a
decrease of 1 °F).
Therefore, using 20 °C (68 °F) as a reference, the specific gravity
reading must be corrected by the following formula :
- Specific gravity at 20 °C = Measured value + 0.0007 x
(electrolyte temperature - 20 °C )
- Specific gravity at 68 °F= Measured value + 0.0004 x
(electrolyte temperature - 68 °F)
Specific Gravity
1.260 Sp. Gr.
1.230 Sp. Gr.
1.200 Sp. Gr.
1.170 Sp. Gr.
1.140 Sp. Gr.
1.110 Sp. Gr.
At an electrolyte temperature of 20 °C (68 °F)
(a) Good
(b) Bad
Tractor Manuals Scotland - Please Do Not Copy
9-S8
ELECTRICAL SYSTEM
State of Charge
100 % Charged
75 % Charged
50 % Charged
25 % Charged
Very Little Useful Capacity
Discharged
(c) Bad
W1022849
KiSC issued 08, 2007 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L3400

Table of Contents