(6) Glow Control System

Tractor Manuals Scotland
Starter Relay
1. Open the panel board and remove the starter relay.
2. Apply battery voltage between terminal 2 and 4, and check for
continuity between terminal 1 and 3.
3. If 0 ohm is not indicated, renew the starter relay.
Resistance
(1) Starter Relay
Glow Plug Lead Terminal Voltage
1. Disconnect the wiring lead (1) from the glow plug (2) after turning
the main switch off.
2. Turn the main switch key to the "PREHEAT" position, and
measure the voltage between the lead terminal and the chassis.
3. Turn the main switch key to the "START" position, and measure
the voltage between the lead terminal and the chassis.
4. If the voltage at either position differs from the battery voltage, the
wiring harness or main switch is faulty.
Voltage (Lead terminal -
Chassis)
(1) Wiring Lead (Positive)
Glow Plug Continuity
1. Disconnect the lead from the glow plugs.
2. Measure the resistance between the glow plug terminal and the
chassis.
3. If 0 ohm is indicated, the screw at the tip of the glow plug and the
housing are short-circuited.
4. If the factory specification is not indicated, the glow plug is faulty.
Glow plug resistance
Tractor Manuals Scotland - Please Do Not Copy
9-S14
ELECTRICAL SYSTEM
0 Ω
1 terminal – 3 terminal
Main switch key at
Approx. battery voltage
"PREHEAT"
Main switch key at
Approx. battery voltage
"START"
(2) Glow Plug
Approx. 0.9 Ω
Factory spec.
W1015050
W1025885
W1015115
KiSC issued 08, 2007 A