Parameter clear / All parameter clear on the operation panel
3.6
Parameter clear / All parameter clear on the
operation panel
POINT
POINT
• Set "1" to Pr.CLR Parameter clear or ALL.CL All parameter clear to initialize parameters. (Parameters cannot be cleared
when Pr.77 Parameter write selection = "1".)
• Pr.CLR does not clear the terminal function selection parameters.
• Refer to the parameter list on
Turning ON the power of the converter
1.
The operation panel is in the monitor mode.
Selecting the parameter setting mode
2.
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
Selecting a parameter number
3.
Turn
to "
"
(initial value)" appears.
Parameter clear
Turn
to change the set value to "
are displayed alternately after parameters are cleared.
4.
Setting
0
Initial display (Parameters are not cleared.)
The settings of parameters except for terminal function
1
selection parameters are initialized.
3.7
Copying and verifying parameters on the
operation panel
Pr.CPY setting
0.---
Initial display
1.RD
Read the parameters from the source converter and store them to the operation panel.
2.WR
Write the parameters stored in the operation panel to the target converter.
3.VFY
Verify parameters in the converter and those in the operation panel. (Refer to
NOTE
• When the copy destination is other than the FR-XC(-PWM) converter or when Parameter copy is attempted after the
parameter copy reading was stopped, the product series error indication "
• Refer to the parameter list on
• When the power is turned OFF or an operation panel is disconnected, etc. during parameter copy writing, perform parameter
copy writing again or check the setting values by using parameter verification.
• If parameters are copied from a not-upgraded converter to an upgraded converter that has additional parameters due to
upgrade, out-of-range setting values may be written in some parameters. In that case, those parameters operate as if they
were set to initial values.
• Parameter copy using the FR-PU07(BB) is available when the product manufactured in September 2015 or later is used.
126
PARAMETERS
page 175
for parameters cleared by Parameter clear or All parameter clear.
Operating procedure
" for Parameter clear or turn it to "
". Press
•Turn
to read another parameter.
•Press
to show the setting again.
•Press
twice to show the next parameter.
Pr.CL Parameter clear
page 175
for the availability of parameter copy.
" for All parameter clear, and press
to enter the setting. "
Description
ALL.CL All parameter clear
The settings of all the parameters, including terminal function
selection parameters, are initialized.
Description
" and "
or
page
128.)
" appears.
.
"