Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual page 84

Fr-xc series multifunction regeneration converter
Table of Contents

Advertisement

Parameter unit (FR-PU07) / Parameter unit with battery pack (FR-PU07BB(-L))
3 Pr.List
key
1
2
3 Pr.List
4 Pr.Clear
5 Alarm His
6 AlarmClear
7 INV.Reset
8 T/Shooting
9 S/W
10 Selectop
11 Option
12 PRCpy set
4 Pr.Clear
5 Alarm His
6 AlarmClear
7 INV.Reset
8 T/Shooting
9 S/W
10 Selectop
11 Option
12 PRCpy set
∗3
The function availability varies
depending on the software version
of the parameter unit.
∗4 Only the copy area 1 is available to
store a parameter setting of the
FR-XC series converter. Do not use
the copy area 2 for any other product
to preserve the converter parameter
setting stored in the copy area 1.
Doing so will delete the converter
parameter setting stored in the copy
area 1.
1 Setting Mode
2 Pr.List
3 Set Pr.List
4 Def.Pr.List
1 1 Clear Pr.
2 Clear All
1 OHT
5 OV2
2 PUE
6 UVT
Fault indications.
3 OV2
7 UVT
The last eight faults are listed.
4 OV2
8 UVT
ALARM CLEAR
Exec<WRITE>
Cancel<ESC>
INV.RESET
An indication "INV.RESET" appears, but this is the function to reset the multifunction regeneration converter.
Exec<WRITE>
Cancel<ESC>
Not available for the FR-XC(-PWM) converter.
<S/W>
An indication "INV" (inverter) appears, but the software version of the multifunction regeneration converter is displayed.
INV:〇〇〇〇 A
Terminal name∗2
The values set in Pr.3 to
Pr.16 are displayed.
ON
∗2
RL
:
0
OFF
RM
:
1
RH
:
2
RT
:
3
<option>
"- - - " means that no corresponding function is assigned to the terminal
OP1: A8NC
(the corresponding parameter in Pr.3 to Pr.16 = "9999") or that the terminal does not have a function.
OP2: ----
OP3: ----
1 Copy area 1
∗4
2 Copy area 2
*3
3 Copy area 3
Copy area 1
1 Read VFD
∗5
2 Write VFD
3 Verifing
∗5
Perform parameter copy
(writing) while the SOF signal
is ON.
SETTING MODE
1 Appl.Grp
0∼9:Ser Pr.No.
2 Pr.List
3 User List
Select Oper
4 Param Copy
0 Pr Mode
⇒ 
1 Max.F
2 Min.F
3 ROH Sel
SET Pr.LIST
36 Fan Oper
12 RYA S
99
⇒ 
65 Retry
3
75 RES Mode
17
0, 1
DEF.Pr.LIST
0 Pr Mo
⇒ 
0
1 Max.F 60.00
2 Min.F 50.00
Clear Pr.
Clear Pr.
        
Exec<WRITE>
Completed
Completed
Cancel<ESC>
Clear All Pr.
Clear All Pr.
Exec<WRITE>
        
Cancel<ESC>
Completed
Completed
ALARM CLEAR
        
Completed
Completed
The terminal names displayed correspond to the converter's terminals as shown below.
RH:
Terminal LOH
RUN:
Terminal RYB
MRS:
Terminal SOF
SU:
Terminal RSO
RES:
Terminal RES
IPF:
Terminal RYA
ABC2:
Terminal ABC
Name: 000
:Select Char
Overwrite area 1
READ:Decide Char
WRITE:Executing
WRITE:DecideName
ESC:Cancel
Param Copy
000
Area 1 to VFD
Writing
Writing
WRITE:Executing
Completed
Completed
ESC:Cancel
Please Reset
000
Param Copy
Verify Area 1
Verifying
Verifying
WRITE:Executing
Completed
Completed
ESC:Cancel
∗1 Perform parameter copy (writing) while the
∗1
SOF signal is ON.
0
000
Param Copy
Reading
Reading
Completed
Completed
PARAMETERS
3
83