Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual page 116

Fr-xc series multifunction regeneration converter
Table of Contents

Advertisement

No.
Item
6
Parameter setting
7
Link parameter
8
extended setting
Model
Product
9
profile
Capacity
Refer to
page 106
for data formats (A, A1, B, B1, C, D, E, E1, and F).
NOTE
• Set 65535 (HFFFF) as a parameter value "9999".
• For the instruction codes HFF and HF3, their values are held once written but cleared to zero when the converter reset or All
parameter clear is performed.
[Special monitor selection No.]
Refer to
page 95
for details of the monitor items.
Data
Description
H01
Input current
H02
Input voltage
H03
Bus voltage
Power supply
H05
frequency
Electronic thermal O/L
H06
relay load factor
H07
Input power
∗1
Input terminal monitor details ("1" denotes terminal ON and "2" denotes terminal OFF.)
∗2
Output terminal monitor details ("1" denotes terminal ON and "2" denotes terminal OFF.)
∗3
Absolute (unsigned) values are displayed.
[Fault data]
Refer to
page 134
for details of faults.
Descript
Data
Data
ion
H00
No fault
HA1
H13
E.A
HA4
H23
E.B
HB0
H30
E.C
HB1
H40
E.D
HB2
H50
E.E
HB3
H51
E.F
HC0
H52
E.G
HC2
H90
E.H
HC5
Read/
Instruction
write
code
Read H00 to H63 Refer to the instruction code list (on
settings as required.
For the setting of Pr.100 or later, the link parameter extended setting is
Write H80 to HE3
required.
Parameter settings are switched (extended) according to a setting from
Read
H7F
H00 to H09.
For details of the settings, refer to the extended code in the instruction
Write
HFF
code list (on
The model name can be read in ASCII code.
"H20" (blank code) is set for blank area.
Read
H7C
Example) "FR-XC":
H46, H52, H2D, H58, H43, H20, ..., H20
The converter capacity can be read in ASCII code.
Data read is displayed in increments of 0.1 kW ( rounded down to one
Read
H7D
decimal place).
"H20" (blank code) is set for blank area.
Example) 7.5K: H20, H20, H20, H20, H37,H35)
Increment
Data
Description
0.01 A
H08
Cumulative power
0.1 V
Cumulative
H09
energization time
0.1 V
Input power with
0.01 Hz
H0A
regenerative driving
indication
0.1%
H0F
Input terminal status
H10
Output terminal status
0.01 kW
b15
0
0
0
0
0
RES
0
b15
0
0
0
0
0
0
0
Descript
Data
ion
E.Q
HF1
E.6
HFD
E.P
HB8
E.J
HB9
E.K
HBA
E.P
HBB
E.L
HF8
E.M
E.N
Data description
page
175) to read/write parameter
page
175).
Increment
Data
1 kWh
H1C
1 h
0.01 kW
∗3
∗1
∗2
SOF
0
LOH
0
0
0
0
0
0
ABC
0
0
0
RYA
Fault monitor details (example of the instruction code H74)
Descript
ion
When data read is H30B1
E.1
(The second latest fault: E.T)
E.L
(The latest fault: E.J)
E.T
b15
E.U
0
0
1
1 0 0 0 0
E.V
E.W
The second latest fault
E.8
(H30)
Parameter details
Number of
data digits
(format)
4 digits
(B and E/D)
4 digits
(A and C/D)
2 digits
(B and E1/D)
2 digits
(A1 and C/D)
20 digits
(B and E3/D)
6 digits
(B and E2/D)
Description
Increment
Electricity cost
b0
0
0
b0
RSO
RYB
b8 b7
b0
1
0
1
1
0
0
0
1
The latest fault
(HB1)
PARAMETERS
1
3
115