Parameter List - Mitsubishi Electric FR-HC2 Series Manual

High power factor converter
Hide thumbs Also See for FR-HC2 Series:

Advertisement

Parameter list

REMARKS
 indicates simple mode parameters.
The parameters shaded in
Parameter write selection.
Parameter
 0
Simple mode selection
 1
Maximum power supply frequency
 2
Minimum power supply frequency
3
ROH terminal function selection
4
SOF terminal function selection
5
X1 terminal function selection
6
X2 terminal function selection
7
RES terminal function selection
8
SOF input selection
9
OH input selection
10
RDY signal logic selection
11
RSO terminal function selection
12
CVO terminal function selection
 13
Y1 terminal function selection
 14
Y2 terminal function selection
 15
Y3 terminal function selection
16
ABC terminal function selection
 22
Current limit level
23
Current limit level (regenerative)
24
OL signal output timer
25
Input current detection level
26
Input current detection signal delay time
27
Input current detection signal retention time
28
Input current detection operation selection
29
Zero current detection level
30
Zero current detection time
31
Life alarm status display
32
Inrush current limit circuit life display
33
Control circuit capacitor life display
34
Maintenance timer
35
Maintenance timer alarm output set time
36
Cooling fan operation selection
Instantaneous power failure detection signal
44
clear
45
AM output filter
46
Watt-hour meter clear
47
Energization time carrying-over times
48
Cumulative power monitor digit shifted times 0 to 4, 9999
Power supply frequency monitoring
49
reference
 50
AM terminal function selection
 51
Input power monitoring reference
 52
DU/PU main display data selection
 53
Input voltage monitoring reference
 54
FM terminal function selection
 55
Bus voltage monitoring reference
 56
Current monitoring reference
 57
Restart selection
allow their settings to be changed during operation even if "1" (write disabled) is set to Pr. 77
Name
0, 9999
60Hz (Read only)
50Hz (Read only)
0 to 5, 9999
0, 1, 2
0, 1
0, 100
0 to 16, 98, 99, 100 to 116,
198, 199, 9999
0 to 220%
0 to 220%, 9999
0 to 25s, 9999
0 to 220%
0 to 10s
0 to 10s, 9999
0, 1
0 to 220%
0 to 1s
0 to 15 (Read only)
0 to 100% (Read only)
0 to 100% (Read only)
0 (1 to 9998)
0 to 9998, 9999
0, 1
0, 9999
0 to 5s
0, 10, 9999
Read only
45Hz to 65Hz
1 to 3, 5, 6, 7, 21,
1111 to 4444
0 to 100kW/0 to 3600kW
0, 5 to 10, 25,
1111 to 4444
0 to 500V
1 to 3, 5, 6, 7, 21,
1111 to 4444
0 to 1000V
0 to 500A/0 to 3600A
0, 9999
Range
Increments
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0.1%
0.1%
0.1s
0.1%
0.1s
0.1s
1
0.1%
0.01s
1
1%
1%
1
1
1
1
0.01s
1
1
1
0.01Hz
1
0.01kW/
*
0.1kW

1
0.1V
1
0.1V
0.01A/0.1A
*
1
Customer
Initial value
setting
0
60Hz
50Hz
5
0
1
2
3
0
0
100
1
2
3
4
5
99
150%
9999
0s
150%
0s
0.1s
0
5%
0.5s
0
100%
100%
0
9999
1
9999
0.01s
9999
0
9999
60Hz
1234
Rated power
1234
220V/440V

1234
340V/680V

Rated current

9999
23