Common Specifications - Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual

Fr-xc series multifunction regeneration converter
Table of Contents

Advertisement

6.2

Common specifications

Input frequency range
Input signal (3)
Output signal
Open collector output (3)
Relay output (1)
Converter
Status
FR-DU08/
monitoring
FR-PU07
Converter
Fault
FR-DU08/
monitoring
FR-PU07
Fault
Protective function
Alarm,
Warning,
Error
message
Surrounding air temperature
Surrounding air humidity
Storage temperature
∗2
Atmosphere
Altitude/vibration
∗1
-10 to +40°C (non-freezing) at the 40°C rating.
∗2
Applicable to conditions for a short time, for example, in transit.
∗3
Not enabled in the initial state.
∗4
Available when the FR-A8NC is installed.
∗5
Displayed on the operation panel (FR-DU08) only.
∗6
Signal assignment is not available for one of the three terminals (terminal RYB).
50 to 60 Hz
The following signals can be assigned to Pr.3, Pr.4, or Pr.7 (Input terminal function selection):
Converter stop (SOF), Converter reset (RES), External thermal relay input (OH), and Box-type
reactor overheat protection (LOH).
The following signals can be assigned to Pr.11, Pr.12, or Pr.16 (Output terminal function
selection): Inverter run enable (RDY), During converter reset (RSO), Converter running (CVO),
Overload warning (OL), Power supply phase detection (PHS), Instantaneous power failure detection
(IPF), Regenerative drive recognition (Y7), Electronic thermal O/L relay pre-alarm (THP), Fan fault
∗6
output (FAN), Heatsink overheat pre-alarm (FIN), During retry (RTY), Life alarm (Y14), Maintenance
timer alarm (Y15), Instantaneous power failure detection hold (Y16), PU stopped (PS), Box-type
reactor overheat pre-alarm (FTP), Alarm (LF), and Fault (ALM).
Input power value (with regenerative driving indication)
Power supply frequency, input current, input voltage, fault indication, bus voltage (output voltage),
electronic thermal relay load factor, cumulative energization time, cumulative power, input power
(with regenerative driving indication), I/O terminal status, electricity cost, option connector status
When a protective function is activated, a fault indication is displayed.
When a protective function is activated, a fault indication is displayed, and the latest monitored value
of input voltage, input current, bus voltage, cumulative energization time are recorded. The last eight
fault records are stored.
Overcurrent trip, Overvoltage trip, Converter overload trip (electronic thermal relay function),
Heatsink overheat, Instantaneous power failure, Undervoltage, Input phase loss, External thermal
relay operation
, Communication option fault
∗3
, CPU fault, Internal circuit fault, 24 VDC power output short circuit, Inrush current
Retry count excess
∗3
limit circuit fault, Connection mode fault, Unsupported control selection, Box-type reactor overheat
protection, Box-type reactor power supply short circuit protection, Option fault
supply detection fault, Input power supply fault 1
Overload signal detection, Electronic thermal relay function pre-alarm, PU stop, Maintenance signal
output
, Power supply not detected, Converter operation disabled, Box-type reactor overheat pre-
∗3
alarm, Fan alarm, Operation panel lock
-10 to +50°C (non-freezing)
90% RH or less (non-condensing)
-20 to +65°C
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt)
2500 m or less (For the installation at an altitude above 1000 m, consider a 3% reduction in the rated
current per 500 m increase in altitude.)
2
5.9 m/s
or less at 10 to 55 Hz (directions of X, Y, Z axes)
, Parameter storage device fault, PU disconnection
∗4
, Write disable error
∗5
∗1
Common specifications
, Main circuit power
∗4
, Copy operation fault
∗5
∗5
SPECIFICATIONS
,
∗3
6
161