For the FR-XC-15K or lower, it is the gauge of a cable with the continuous maximum permissible temperature of 70°C (PVC cable). It assumes a surround-
ing air temperature of 40°C or less and the wiring distance of 20 m or less from the power supply to the converter.
For the FR-XC-22K / FR-XC-18.5K-PWM or higher, it is the gauge of a cable with the continuous maximum permissible temperature of 90°C (PVC cable). It
assumes a surrounding air temperature of 40°C or less and the wiring distance of 20 m or less from the power supply to the converter.
(Selection example mainly for use in Europe.)
∗4
If a cable thinner than the recommended cable size is used, it may not be protected by the DC fuse. (Refer to
∗5
Refer to the Inverter Instruction Manual.
• 400 V class
Model
Rating
50°C
FR-XC-H7.5K
40°C
50°C
FR-XC-H11K
40°C
50°C
FR-XC-H15K
40°C
50°C
FR-XC-H22K
FR-XC-H18.5K-PWM
40°C
FR-XC-H30K
50°C
FR-XC-H22K-PWM
40°C
50°C
FR-XC-H37K
FR-XC-H37K-PWM
40°C
50°C
FR-XC-H55K
FR-XC-H55K-PWM
40°C
Model
Rating
50°C
FR-XC-H7.5K
40°C
50°C
FR-XC-H11K
40°C
50°C
FR-XC-H15K
40°C
50°C
FR-XC-H22K
FR-XC-H18.5K-PWM
40°C
50°C
FR-XC-H30K
FR-XC-H22K-PWM
40°C
50°C
FR-XC-H37K
FR-XC-H37K-PWM
40°C
50°C
FR-XC-H55K
FR-XC-H55K-PWM
40°C
∗1
It is the gauge of a cable with the continuous maximum permissible temperature of 75°C (HIV cable (600 V grade heat-resistant PVC insulated wire), etc.).
It assumes a surrounding air temperature of 50°C or less (40°C or less for the 40°C rating) and the wiring distance of 20 m or less from the power supply to
the converter.
∗2
The cable size is that of the THHW cable with continuous maximum permissible temperature of 75°C. It assumes a surrounding air temperature of 40°C or
less and the wiring distance of 20 m or less from the power supply to the converter.
(For the use in the United States or Canada, refer to
∗3
For the FR-XC-15K or lower, it is the gauge of a cable with the continuous maximum permissible temperature of 70°C (PVC cable). It assumes a surround-
ing air temperature of 40°C or less and the wiring distance of 20 m or less from the power supply to the converter.
For the FR-XC-22K / FR-XC-18.5K-PWM or higher, it is the gauge of a cable with the continuous maximum permissible temperature of 90°C (PVC cable). It
assumes a surrounding air temperature of 40°C or less and the wiring distance of 20 m or less from the power supply to the converter.
(Selection example mainly for use in Europe.)
∗4
If a cable thinner than the recommended cable size is used, it may not be protected by the DC fuse. (Refer to
∗5
Refer to the Inverter Instruction Manual.
Crimp terminal (for HIV cables, etc.)
FR-XC
1.25-4
3.5-5
3.5-6
1.25-4
1.25-4
3.5-5
3.5-6
1.25-4
1.25-4
3.5-5
5.5-6
1.25-4
14-6
1.25-4
8-8
1.25-4
8-6
14-8
1.25-4
14-6
1.25-4
8-8
22-8
1.25-4
22-8
1.25-4
14-8
1.25-4
38-8
38-8
1.25-4
Cable gauge
2
HIV cables, etc. (mm
)
∗1
Location in the
Earth
connection diagram
connection diagram
(ground)
a, b
c
d
a, b
∗4
3.5
12
3.5
3.5
1.25
3.5
3.5
3.5
12
3.5
5.5
1.25
5.5
12
14
10
8
1.25
8
8
14
14
1.25
14
8
22
22
1.25
14
14
38
38
1.25
22
page
179.)
Main circuit terminal specification
page 21
Model
3.5-4
FR-XCL-H7.5K
3.5-5
FR-XCL-H11K
5.5-5
FR-XCL-H15K
8-6
FR-XCL-H22K
14-6
FR-XCL-H30K
14-8
FR-XCL-H37K
22-8
FR-XCL-H55K
Cable gauge
AWG/MCM
PVC cables, etc. (mm
∗2
Location in the
Location in the
connection diagram
c
d
a, b
c
12
16
4
4
12
16
4
4
12
16
4
4
10
8
16
6
10
8
8
6
16
10
10
6
4
16
16
16
4
2
16
25
25
2
page 21
INSTALLATION AND WIRING
for the fuse selection.)
Crimp terminal
(for HIV cables, etc.)
Rating
FR-XCL
50°C
3.5-5
40°C
50°C
3.5-5
40°C
50°C
3.5-5
40°C
50°C
8-6
40°C
50°C
14-6
40°C
8-6
50°C
22-8
40°C
14-8
50°C
38-8
40°C
2
)
∗3
Earth
(ground)
d
1.5
4
1.5
4
1.5
4
1.5
10
1.5
10
1.5
16
1.5
16
for the fuse selection.)