Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual page 86

Fr-xc series multifunction regeneration converter
Table of Contents

Advertisement

Pr.
Name
Reset selection /
75
disconnected PU detection /
PU stop selection
77
Parameter write selection
Voltage control proportional
80
∗4
gain
81
Voltage control integral gain
∗4
Current control proportional
82
∗4
gain
83
Current control integral gain
∗4
PU communication station
117
number
118
PU communication speed
PU communication stop bit
119
length
PU communication parity
120
check
PU communication retry
121
count
PU communication waiting
123
time setting
PU communication CR/LF
124
selection
PU display language
145
selection
168
169
Parameter for manufacturer setting. Do not set.
269
Communication EEPROM
342
write selection
415
SW2 setting status
416
Control method selection
Communication error
500
∗1
execution waiting time
Communication error
501
∗1
occurrence count display
Stop mode selection at
502
∗1
communication error
520
Parameter for manufacturer setting. Do not set.
542
,
,
Station number (CC-Link)
∗1
∗2
∗3
Transmission speed
543
,
,
∗1
∗2
∗3
selection (CC-Link)
544
,
CC-Link extended setting
∗1
∗2
896
Power unit cost
989
Parameter for manufacturer setting. Do not set.
990
PU buzzer control
991
PU contrast adjustment
Pr.CLR
Parameter clear
ALL.C
All parameter clear
Err.CL
Fault history clear
Pr.CPY
Parameter copy
∗1
The setting is available only when a communication option (FR-A8NC) is installed.
∗2
The setting is applied after the converter reset or next power-ON.
∗3
[L.ERR] LED indicator on the FR-A8NC blinks when a setting is changed. The setting is applied after the converter reset, and the [L.ERR] turns
OFF.
∗4
The setting is available only when the harmonic suppression is enabled.
Setting range
0 to 3, 14 to 17
1
1, 2
1
0 to 1000%
1%
0 to 1000%
1%
0 to 200%
1%
0 to 200%
1%
0 to 31
1
48, 96, 192, 384
1
0, 1, 10, 11
1
0 to 2
1
0 to 10, 9999
1
0 to 150 ms, 9999
1 ms
0 to 2
1
0 to 7
1
0, 1
1
0 to 15 (Read only)
1
0, 1, 9999
1
0 to 999.8 s
0.1 s
0
1
0, 3
1
1 to 64
1
0 to 4
1
0, 1, 12
1
0 to 500
0.01
0, 1
1
0 to 63
1
(0), 1
1
(0), 1
1
(0), 1
1
(0), 1 to 3
1
Minimum
setting
Initial value
increment
14
2
100
100
100
100
0
192
1
2
1
9999
1
0
0
15
9999
0 s
0
0
1
0
0
0
1
58
0
0
0
0
PARAMETERS
Parameter list
Refer to
Customer
page
setting
Pr.
100
list
101
90
90
102
102
104
104
104
104
104
104
104
125
124
94
40
123
123
123
117
117
117
96
3
125
125
126
126
143
127
85