Component Names - Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual

Fr-xc series multifunction regeneration converter
Hide thumbs

Advertisement

Table of Contents

Component names

1.2
Component names
Component names are shown below.
30K converters or lower
(b)
Symbol
(a)
Control circuit terminal block cover
Communication operation status
(b)
inspection port
(for the FR-A8NC)
(c)
Main control circuit terminal block cover Remove it for wiring.
(d)
PU connector
Operation status 7-segment LED
(e)
display
(f)
Control circuit terminal block
(g)
Control logic switchover jumper connector
(h)
Charge lamp
(i)
Main circuit terminal block
(j)
Connector for manufacturer setting
(k)
Cooling fan
(l)
Connector for communication option
Function selection switch assembly
(m)
(SW2)
14
OUTLINE
(a)
(c)
Name
Remove it for installing a communication option, wiring the control circuit
terminals, or changing the SW2 switches.
Check the state (ON/blinking) of the communication operation status
indicators on the communication option (FR-A8NC) when the option is
installed.
Connector for parameter units. Also used for the RS-485 communication.
Check the display indication or LED state (ON/blinking) for the operation
status of the converter.
Connect cables for the control circuit.
Change the control logic of input signals as necessary.
Stays ON while the power is supplied to the main circuit.
Connect cables for the main circuit.
Do not remove the cap from the connector.
Cools the multifunction regeneration converter.
Connect cables for the communication option (FR-A8NC).
1: Connection mode (common bus regeneration mode
/ power regeneration mode) selection
2: For manufacturer setting
3: Temperature derating selection
4: For manufacturer setting
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(i)
Description
(k)
(l)
(m)
(i)
(i)
Refer
to page
26
26
103
72
50
51
72
41
149
71
10

Advertisement