Remote register (Refer to
● When "One station occupied (FR-A5NC compatible)" for the CC-Link Ver. 1 is selected (Pr.544 = "0")
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
RWwn+2
H00 (arbitrary)
RWwn+3
("n" indicates a value determined by the station number setting.)
∗1
The upper 8 bits always contains H00 even a different value is set.
● When "One station occupied" for the CC-Link Ver. 1 is selected (Pr.544 = "1")
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Link parameter
RWwn+2
extended setting
RWwn+3
("n" indicates a value determined by the station number setting.)
● When "One station occupied, double setting" for the CC-Link Ver. 2 is selected (Pr.544 = "12")
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Link parameter
RWwn+2
extended setting
RWwn+3
RWwn+4
RWwn+5
RWwn+6
RWwn+7
("n" indicates a value determined by the station number setting.)
page
121.)
Description
Lower 8 bits
Monitor code 1
Unused
Instruction code
∗1
Data to be written
Description
Lower 8 bits
Monitor code 1
Unused
Instruction code
Data to be written
Description
Lower 8 bits
Monitor code 1
Unused
Instruction code
Data to be written
Monitor code 3
Monitor code 4
Monitor code 5
Monitor code 6
Address
Upper 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
RWrn+3
Address
Upper 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code
RWrn+3
Address
Upper 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code
RWrn+3
RWrn+4
Third monitor value
RWrn+5
Fourth monitor value
RWrn+6
Fifth monitor value
RWrn+7
Sixth monitor value
Parameter details
Description
Lower 8 bits
Reply code
Data read
Description
Lower 8 bits
H00
Data read
Description
Lower 8 bits
H00
Data read
119