Rating; Fr-Xc-K - Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual

Fr-xc series multifunction regeneration converter
Table of Contents

Advertisement

Rating

6.1
Rating
6.1.1
FR-XC-[ ]K
200 V class
Model FR-XC-[ ]K
Applicable inverter
capacity (kW)
Applicable motor current
(A)
Rated input current (A)
Overload current rating
Power supply capacity
(kVA)
∗2
Applicable inverter
capacity (kW)
Applicable motor current
(A)
Rated input current (A)
Overload current rating
Power supply capacity
(kVA)
∗2
Potential regenerative capacity (kW)
Rated current (A) (regenerative driving)
Overload current rating
Potential regenerative capacity (kW)
Rated current (A) (regenerative driving)
Overload current rating
Rated input AC voltage/
frequency
Permissible AC voltage
fluctuation
Permissible frequency
fluctuation
Input power factor
Protection rating of structure (IEC 60529)
Cooling system
Number of connectable inverters
Approx. mass (kg)
∗6
∗1
The harmonic suppression function is not pre-enabled in this model.
∗2
Selection example for 220 V power supply voltage.
∗3
IP00 for the FR-XCL.
∗4
The DC bus voltage is approx. 297 VDC at an input voltage of 200 VAC, approx. 327 VDC at 220 VAC, and approx. 342 VDC at 230 VAC.
∗5
One inverter for operation in the power regeneration mode.
∗6
Mass of the FR-XC alone.
∗7
Maximum capacity of regenerative power generated from the Mitsubishi Electric 4-pole standard motor in each axis.
156
SPECIFICATIONS
∗1
Harmonic suppression
Disabled
Enabled
Disabled
Enabled
Power driving
Disabled
Regenerative
driving
Power/
Enabled
regenerative
(HS)
driving
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Power driving
Disabled
Regenerative
driving
Power/
Enabled
regenerative
(HS)
driving
Disabled
Enabled
∗7
∗7
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Enabled
7.5
11
15
22
7.5
11
15
22
18.5
33
46
61
90
76
33
47
63
92
26
37
51
74
69
100% continuous / 150% 60 s
17
20
28
41
30
7.5
11
15
22
18.5
36
50
67
99
83
36
51
69
101
28
40
56
81
75
100% continuous / 150% 60 s
19
22
31
45
32
5.5
7.5
11
18.5
19
26
37
62
100% continuous / 150% 60 s
5.5
7.5
11
18.5
21
28
40
68
100% continuous / 150% 60 s
Three-phase 200 to 240 V, 50/60 Hz
Three-phase 200 to 230 V, 50/60 Hz
Three-phase 170 to 264 V, 50/60 Hz
Three-phase 170 to 253 V, 50/60 Hz
±5%
0.99 or more (when load ratio is 100%)
Open type (IP00)
Forced air
10
5
5
6
10.5
30
37
55
30
37
55
22
37
55
115
145
215
90
145
215
124
151
223
102
125
186
82
134
198
52
66
100
35
57
84
30
37
55
22
37
55
127
160
236
99
160
236
136
166
245
112
138
204
90
147
217
57
73
110
38
62
92
22
30
45
74
102
152
22
30
45
81
112
167
±5%
∗3
∗5
10.5
28
38
∗4