INSTALLATION MANUAL FOR A-M CONVERTER
This manual is written only for the models
PU(H)-P1〜4VGA(A), PU(H)- P25〜100VGAA
PU(H)-P1.6〜6YGA(A), PU(H)-P35〜140YGAA,
PUHZ-RP1.6〜6VHA(-A), PUHZ-RP35〜140VHA(-A)
PUHZ-RP4〜6YHA, PUHZ-RP100〜140YHA
PUHZ-RP8/10YHA(-A), PUHZ-RP200/250YHA(-A)
PUH-P8/10YE, PUH-P8/10MYA, PUH-P200/250MYA
Before starting installation, read the "Safety Precautions" described below. 
The following precautions must be observed as it describes the serious matters for safety. 
The safety precautions are described with the degree of danger.
WARNING
When you handle wrong, it can lead to death or serious injury.
CAUTION
When you handle wrong, it can lead to injury or damage to building and furniture.
After installation, make test operation and confirm that it works properly, and explain the safety precautions, operation method, and  
  maintenance to your customers.  
  Tell your customers to keep this installation manual together with operation manual with them, and when they give or sell this machine  
  to other person put this installation manual and operation manual with it.
The installation must be done by dealer or qualified person.
If the customers do the installtion by themselves and it is not perfectly  
  installed it can cause water leak, electric shock, or fire.
The installation must be done in accordance with this manual.
 
If the installation is not perfectly done, it can cause water leak, electric  
  shock, or fire. 
 
Never try any modification.
For repair, ask your dealer.   
  If the machine is modified or repaired unperfectly, it can cause water  
  leak, electric shock, or fire.
Never move or reinstall the machine by the customers.
If the installation is not perfectly done, it can cause water leak, electric  
  shock, or fire.  Ask your dealer or qualified person.
Before electric wiring
Install a circuit breaker depending upon the location.
Without a circuit breaker, it can cause electric shock.
Use standard wires which meet current capacity.
Otherwise, it can cause short-circuit, heat, or fire.
Wires must not have tension.
It can cause snipping, heat, or fire.
Before test operation
Turn the power on 12 hours or more before operation.
If you start operation as soon as the power on, it can cause failure.   
  Never turn the power off during season.
Never operate the machine without panel or guard off.
It can cause serious injury being caught by rotating part or burn or  
  electric shock by high voltage part.
Never operate the machine without air filter off.
It can cause failure by dust.
SAFETY PRECAUTIONS
WARNING
CAUTION
CAUTION
The wiring must be securely done by using proper cable. The wires should
be connected to the terminals not to have external force of the cable.
Unperfect connections can cause heat or fire.
The termial cover (panel) of the unit must be installed securely.
Unperfect installation can cause fire or electric shock by dust or water.
The electric installation must be done by qualified person in accordance
with this installation manual. Use the separate circuit only for this machine
and use rated voltage and circuit breaker.
If the electric circuit power is not sufficient or the wiring is not properly  
  done, it can cause electric shock or fire.
Put ground wire.
Never ground to gas pipe, water pipe, lightning conductor, or  
  telephone ground wire.   
  Unperfrect ground can cause short-circuit.
Use proper fuses
If you use larger size fuses or neelde wire, it can cause failure or fire.
Never operate the switches with your hand wet.
It can cause electric shock.
Never touch refrigerant pipes while the machine running.
The refrigerant pipes becomes high and low temperature while the  
  machine running. If you touch the pipes by hand, it can cause chilblain 
  or burn.
Never turn the power off as soon as the machine stops.
Wait for 5 minutes or more.  It can cause water leak or failure.
 
RG79N659H07
PAC-SF70MA-E

Advertisement

loading

Summary of Contents for Mitsubishi Electric PU-P1-4VGA

  • Page 1 RG79N659H07 PAC-SF70MA-E INSTALLATION MANUAL FOR A-M CONVERTER This manual is written only for the models PU(H)-P1〜4VGA(A), PU(H)- P25〜100VGAA PU(H)-P1.6〜6YGA(A), PU(H)-P35〜140YGAA, PUHZ-RP1.6〜6VHA(-A), PUHZ-RP35〜140VHA(-A) PUHZ-RP4〜6YHA, PUHZ-RP100〜140YHA PUHZ-RP8/10YHA(-A), PUHZ-RP200/250YHA(-A) PUH-P8/10YE, PUH-P8/10MYA, PUH-P200/250MYA SAFETY PRECAUTIONS Before starting installation, read the "Safety Precautions" described below.  ● The following precautions must be observed as it describes the serious matters for safety.  ● The safety precautions are described with the degree of danger. ● WARNING When you handle wrong, it can lead to death or serious injury. CAUTION When you handle wrong, it can lead to injury or damage to building and furniture. After installation, make test operation and confirm that it works properly, and explain the safety precautions, operation method, and   ●   maintenance to your customers.     Tell your customers to keep this installation manual together with operation manual with them, and when they give or sell this machine     to other person put this installation manual and operation manual with it.
  • Page 2: Parts List

    1. Parts List Applicable models  A : PUHZ-RP1.6/2VHA(−A), RP35/50VHA(−A)  D : PUH-P8/10YE, P8/10MYA, P200/250MYA  B : PUHZ-RP2.5〜6VHA(−A), RP60〜140VHA(−A)  E : PUHZ-RP4〜6YHA, RP100〜140YHA  C : PU(H)-P1〜4VGA(A), P25〜100VGAA,   F : PUHZ-RP8/10YHA(−A), RP200/250YHA(−A)       PU(H)-P1.6〜6YGA(A), P35〜140YGAA   Applicable models №  Description Figure Q'ty  Note M-NET board   (with insulation  ①  ○  ○  ○  ○  ○  ○  sheets and   supports) Plate   (For mounting  ②  ○  circuit board)   ○    Insulation sheets   ③      ○   ...
  • Page 3 RG79N659H09 2. Installation procedure  【 PU (H) -P1〜4VGA (A) , P25〜100VGAA, PU (H) -P1.6〜6YGA (A) , P35〜140YGAA】        Install the M-NET board ① so that the       (SW11, SW12) come front.  ①M-NET board      ※Put it securely until it sounds click.    Address switches        Install the Terminal block (M-NET) ⑥ on  the Terminal base ④.       ※The  Terminal  base  ④  has  round  boss              for positioning.          Match the round boss to the holes of          the Terminal base ④.         Put the Label ⑧ on the Terminal base ④.       ※Not to close the Hole for M-NET ground.         Install the Terminal base ④ on the bottom  Control board inside of the electric box. ...
  • Page 4 2. Installation procedure  【 PUH-P8/10YE, P8/10MYA, P200/250MYA】          Install the M-NET board ① so that the  ①M-NET board      (SW11, SW12) come front.       ※Put it securely until it sounds click.    SW12 SW11       Address switches      Install the Terminal block (M-NET) ⑥ on  the base of the electric box.             Put the Label ⑧ on the base of the  electric box.                Control board                 Mounting hole    ...
  • Page 5 RG79N659H11 2. Installation procedure  【 PUHZ-RP1.6/2VHA (−A) , RP35/50VHA (−A) 】     ●To protect the wires connected to M-NET board from the edges of          Affix insulation sheets   and  ③ to the   sheet-metal component, paste the insulation on the edge surface of panel  backside of the flange surface on the top   sheet-metal before proceeding with the following work. of the side panel.          ③Insulation sheet                   Starting from the bottom, mount lnsulation    ③Insulation sheet  Sheet   ③ to the  L  bend section on  the back of the noise filter mounting panel.         Position the chamfered section of Plate   ② so that it faces the fan side (the left ...
  • Page 6 2. Installation procedure  【 PUHZ-RP2.5〜6VHA (−A) , RP60〜140VHA (−A) 】   ●To protect the wires connected to M-NET board from the edges of      sheet-metal component, paste the insulation on the edge surface of panel       Pate insulation sheet   ③ on sheet-metal   sheet-metal before proceeding with the following work. so that it completely envelops the edge  surface of sheet-metal.    Paste insulation sheet   ③ on sheet-metal so that it     completely envelops the edge surface of sheet-metal.                                Install M-NET board ① (with insulation  (When viewed from the side of Electric box)  sheets and supports) on the side of  Electric box so that the rotary switch  faces up (at the four points indicated by  ①M-NET board arrows). ...
  • Page 7 RG79N659H12 2. Installation procedure  【 PUHZ-RP4〜6YHA, PUHZ-RP100〜140YHA】   Control board      Attach the Plate 2 ⑮, using two screws⑤.           Install M-NET board ① (with insulation  sheets and supports) on the Plate2 ⑮ .       ※Push it firmly until you hear it  click .             Use terminal screw ⑦ to secure terminal  block⑥        ※Terminal block⑥ has a round boss for  positioning:Fit the round boss into the  positioning hole in steel-plate.           Paste label ⑧            Use lead wire-A ⑨ to connect CN5 of   M-NET board ① connection and CNMNT  of outdoor control board.       ※Caution  Wire Marking:R410A, Connector color:Red  Always make sure that the markings and  CENTRALIZED CONTROL(M-NET) the applicable model match. If used  A  B  S  ⑧Label incorrectly, parts could be damaged.  B G79H744H02    ...
  • Page 8 2. Installation procedure  【 PUHZ-RP8/10YHA (−A) , RP200/250YHA】          Install M-NET board ① (with insulation  (When viewed from the side of electrical parts box) sheets and supports) on the side of  electric box .  At the four point indicated by arrows.  Control board      ※Push it firmly until you hear it  click .             Use terminal screw ⑦ to secure terminal  block⑥        ※Terminal block⑥ has a round boss for  positioning:Fit the round boss into the  positioning hole in steel-plate.           Paste label ⑧ under terminal block ⑥           Use lead wire-A ⑨ to connect CN5 of   M-NET board ① connection and CNMNT  of outdoor control board.       ※Caution  Wire Marking:R410A, Connector color:Red  Always make sure that the markings and  the applicable model match. If used  incorrectly, parts could be damaged.      Use lead wire-C ⑪ to connect CND of   M-NET board ① connection and  CNVMNT of outdoor control board.  ...
  • Page 9 RG79N659H10 3. Wiring method for M-NET (1) Attention  ① Outside of the unit, the wires for transmission (called for transmit wires later) should keep away (5 cm or more)       from power cable not to receive electric noise.   ( Never put the transmit wires and power cable in the same cable pipe.)  ② Never supply voltage 220V-240V to the terminals (TB7) for transmission.  If the voltage is supplied, it can break       the electronic parts on the A-M CONVERTER board.  ③ Use the shielded cable (CVVS, CPEVS) of 1.25mm square thickness with 2 wires for the transmission cable.        Never use transmit wires of different system with a cable which contains multi wires.        The communication of transmit signals will not work properly and       it can cause wrong operation.      Group remote   Refrigerant address  Refrigerant address  Refrigerant address  controller M-NET address  M-NET address  M-NET address  Power supply unit  for transmit cable (                ) (                ) (                ) Slim A control  Slim A control  Slim A control  remote control remote control remote control Between the outdoor units, it is OK that only M-NET wiring (2 wires, no polarity) is done. (2) M-NET address setting       Make M-NET setting and refrigerant address setting on only outdoor unit.         There is no address settings for outdoor unit and remote controller like City Multi system.         The M-NET address setting for taking into centralized control system should be done only to the outdoor unit.         The address set number should be 1-50 same as for City Multi indoor unit and make set in order of number for       the same group. ...
  • Page 10 (3) Refrigerant address setting       In case that the A control Slim is set for group between different refrigerant (when multiple refrigerant        system is set in one group), it is necessary to make refrigerant address setting besides the wiring for        remote controller (TB5) between the indoor untis.         In case that the group setting is not done, be sure to leave the refrigerant address set for 00.         The refrigerant address is set by dip switch SW1 (3-6) on the outdoor controller of the outdoor unit.         (Factory settings are all OFF  ・ ・ ・ ・ ・ Refrigerant address 00).    (SW1)       1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6...
  • Page 11 RG79N659H08 Attention for A control Slim M-NET connection Pay attention to the next points for wiring of shielded wires. CAUTION The shielded wires of M-NET transmission should be connected with the   ground wire at any only one place of the unit to be connected.    It can cause the transmission error due to noise.    Outdoor unit digital LED display reads "Ed" error.    Centralized control remote controller reads "0403" error.    ×Bad example (Multiple ground of shielded wire)   Centralized   Outdoor unit   Outdoor unit   Outdoor unit   Power supply   control remote   corresponds  corresponds  corresponds  unit controller  to M-NET  to M-NET  to M-NET M-NET transmit wire ○Good example (One spot ground of shielded wire) Centralized   Outdoor unit   Outdoor unit   Outdoor unit   Power supply   control remote   corresponds  corresponds  corresponds  unit controller  to M-NET  to M-NET  to M-NET...
  • Page 12 HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN  ...