Download  Print this page

Appendix 2 Instruction Code List - Mitsubishi Electric FR-XC-18.5K-PWM Instruction Manual

Fr-xc series multifunction regeneration converter
Hide thumbs

Advertisement

Table of Contents
Appendix 2
∗1
The instruction code is used to write or read parameters through RS-485 communication or CC-Link communication.
(For RS-485 communication, refer to
∗2
For Parameter copy, Parameter clear, and All parameter clear, ○ indicates the function is available, and × indicates the function is not available.
∗3
These parameters are not cleared by Parameter clear command or All parameter clear command sent through RS-485 communication or CC-
Link communication. (For RS-485 communication, refer to
∗4
Reading and writing are enabled when commands are sent through communication via the PU connector.
The parameter marked with the following option icon is available when the corresponding option is installed.
: FR-A8NC
Pr.
Name
0
Simple mode selection
Maximum power supply
1
frequency
2
Minimum power supply frequency 02 82
3
LOH terminal function selection
4
SOF terminal function selection
7
RES terminal function selection
8
SOF input selection
9
OH input selection
11
RSO terminal function selection
12
RYA terminal function selection
16
ABC terminal function selection
22
Current limit level
23
Current limit level (regenerative)
31
Life alarm status display
Inrush current limit circuit life
32
display
Control circuit capacitor life
33
display
34
Maintenance timer
Maintenance timer warning
35
output set time
Instantaneous power failure
44
detection signal clear
46
Watt-hour meter clear
Energization time carrying-over
47
times
Cumulative power monitor digit
48
shifted times
52
PU main monitor selection
57
Restart selection
58
Free parameter 1
59
Free parameter 2
61
Key lock operation selection
65
Retry selection
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Reset selection / disconnected
75
PU detection / PU stop selection
77
Parameter write selection
∗4
80
Voltage control proportional gain
81
Voltage control integral gain
82
Current control proportional gain
83
Current control integral gain
PU communication station
117
number
118
PU communication speed
119
PU communication stop bit length 13 93
120
PU communication parity check
Instruction code list
page
105. For CC-Link communication, refer to
page
Instruction
Parameter
code
∗1
00 80
0
×
×
01 81
0
0
×
×
×
03 83
0
04 84
0
×
×
07 87
0
08 88
0
×
×
09 89
0
×
0B 8B
0
×
0C 8C
0
×
10 90
0
16 96
0
17 97
0
1F 9F
0
×
×
20 A0
0
×
×
×
×
21 A1
0
×
×
×
22 A2
0
23 A3
0
×
2C AC
0
×
×
×
×
2E AE
0
×
×
×
2F AF
0
30 B0
0
34 B4
0
39 B9
0
×
×
3A BA
0
3B BB
0
×
×
×
3D BD
0
41 C1
0
43 C3
0
44 C4
0
45 C5
0
×
×
4B CB
0
4D CD
0
50 D0
0
51 D1
0
52 D2
0
53 D3
0
11 91
1
 
∗3
∗3
12 92
1
 
∗3
∗3
1
 
∗3
∗3
14 94
1
 
∗3
∗3
page
117.)
105.) For CC-Link communication, refer to
Pr.
Name
121
PU communication retry count
PU communication waiting time
123
setting
PU communication CR/LF
124
selection
145
PU display language selection
168,
169,
Parameter for manufacturer setting. Do not set.
269
Communication EEPROM write
342
selection
415
SW2 setting status
416
Control method selection
Communication error execution
500
waiting time
Communication error occurrence
501
count display
Stop mode selection at
502
communication error
520
Parameter for manufacturer setting. Do not set.
542
Station number (CC-Link)
Transmission speed selection
543
(CC-Link)
544
CC-Link extended setting
896
Power unit cost
989
Parameter for manufacturer setting. Do not set.
990
PU buzzer control
991
PU contrast adjustment
page
117.)
Instruction
Parameter
code
∗1
15 95
1
 
∗3
∗3
17 97
1
 
∗3
∗3
18 98
1
 
∗3
∗3
2D AD
1
×
×
2A AA
3
×
×
×
0F 8F
4
×
×
10 90
4
00 80
5
×
01 81
5
02 82
5
2A AA
5
 
∗3
∗3
2B AB
5
 
∗3
∗3
2C AC
5
 
∗3
∗3
60 E0
8
5 A DA
9
×
5B DB
9
175
APPENDIX

Advertisement

Table of Contents
loading

  Related Manuals for Mitsubishi Electric FR-XC-18.5K-PWM