Siemens RUGGEDCOM ROX II User Manual page 595

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

RUGGEDCOM ROX II
CLI User Guide
LABEL
LABEL
--------------------------------------------
200
205
215
250
This table provides the following information:
Parameter
local-label
outgoing-label
outgoing-interface
next-hop
If no static cross-connects have been configured, add cross-connects as needed. For more information about
adding static cross-connects, refer to
Section 13.10.6.2
Viewing a List of Static Cross-Connects
To view a list of configured static cross-connects, type:
show running-config mpls static-mpls crossconnects
If static cross-connects have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config mpls static-mpls crossconnect | tab
OUT
LABEL
INTERFACE
-----------------------------------------
20
switch.0001
!
!
If no static cross-connects have been configured, add cross-connects as needed. For more information about
adding static cross-connects, refer to
Section 13.10.6.3
Adding a Static Cross-Connect
To add a static cross-connect, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add a static cross-connect by typing:
mpls static-mpls crossconnect in-label in-label
Where:
• in-label is the incoming label
Viewing a List of Static Cross-Connects
INTERFACE
NEXT HOP
switch.0010
192.168.10.2
switch.0010
192.168.10.2
Synopsis:   A string
The incoming (local) label.
Synopsis:   A string
The outgoing (remote) label.
Synopsis:   A string
The outgoing interface.
Synopsis:   A string
The destination next hop router.
Section 13.10.6.3, "Adding a Static
OUT
NEXT HOP
LABEL
192.168.10.2
32
Section 13.10.6.3, "Adding a Static
Unicast and Multicast Routing
Description
Cross-Connect".
Cross-Connect".
Chapter 13
549