Siemens RUGGEDCOM RSG2100PF Installation Manual

Siemens RUGGEDCOM RSG2100PF Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2100PF:

Advertisement

Quick Links

RUGGEDCOM RSG2100PF
Installation Guide
6/2019
RC1345-EN-05
Preface
Introduction
Installing Device
Device Management
Communication Ports
Technical Specifications
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSG2100PF

  • Page 1 Preface Introduction Installing Device RUGGEDCOM RSG2100PF Device Management Communication Ports Technical Specifications Installation Guide Certification 6/2019 RC1345-EN-05...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RSG2100PF Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario https://www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RSG2100PF Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RSG2100PF   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 6   RUGGEDCOM RSG2100PF Table of Contents Installation Guide Chapter 3 Device Management ..................3.1  Connecting to the Device ......................19 3.2  Configuring the Device ........................ 20 Chapter 4 Communication Ports ..................4.1  Copper Ethernet Ports ......................... 22 4.2    PoE Ports ............................ 24 4.3  Fiber Optic Ethernet Ports ......................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG2100PF. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9: Customer Support

    RUGGEDCOM RSG2100PF   Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
  • Page 10   RUGGEDCOM RSG2100PF Preface Installation Guide Customer Support...
  • Page 11: Introduction

    (ST, MTRJ, LC, SC) without loss of port density. The RUGGEDCOM RSG2100PF is an ideal solution to power and connect several Ethernet devices, such as IP phones, video cameras, and wireless access points, where AC power is not available or where it is cost-prohibitive to provide locally.
  • Page 12: Description

    Section 1.2 Description The RUGGEDCOM RSG2100PF features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 13: Required Tools And Materials

    Section 3.1, “Connecting to the Device”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2100PF: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. CAT-5 Ethernet cables For connecting the device to the network.
  • Page 14: Decommissioning And Disposal

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15: Gigabit Ethernet 1000Base-Tx Cabling Recommendations

    RUGGEDCOM RSG2100PF Chapter 1 Installation Guide Introduction Section 1.5.2 Gigabit Ethernet 1000Base-TX Cabling Recommendations The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet communications over distances of up to 100 m (328 ft) using all 4 pairs in category 5 (or higher) balanced, unshielded twisted-pair cabling. For wiring...
  • Page 16: Tamper-Evident Security Seals

    IMPORTANT! Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. There are three ways to determine if a security seal has been tampered with: •...
  • Page 17: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 18: Unpacking The Device

    Mounting the Device The RUGGEDCOM RSG2100PF is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail, or directly on a panel.
  • Page 19: Mounting The Device To A Rack

    Section 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2100PF can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 20: Mounting The Device On A Din Rail

    Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2100PF can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 21: Mounting The Device To A Panel

    Section 2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG2100PF can be equipped with panelDIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 22: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROS-F. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS-F User Guide for the RUGGEDCOM RSG2100PF. The following shows the proper relay connections.
  • Page 23: Connecting Power

    1. Normally Open    2. Common    3. Normally Closed Section 2.5 Connecting Power The RUGGEDCOM RSG2100PF supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RSG2100PF can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power supply and PoE ports.
  • Page 24: Connecting Ac Or Dc Power

    Chapter 2 RUGGEDCOM RSG2100PF Installing Device Installation Guide Section 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the field, remove the metal jumper.
  • Page 25: Connecting External Poe Power

    Install the terminal block cover. Section 2.5.2 Connecting External PoE Power The RUGGEDCOM RSG2100PF supports up to four 10/100Base-TX Power-over-Ethernet (POE) Ports that require power from an external source. NOTE For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in).
  • Page 26: Wiring Examples

    Chapter 2 RUGGEDCOM RSG2100PF Installing Device Installation Guide Connecting the External Power Supply To connect an external power supply for the PoE ports, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Only connect the external PoE power supply to the terminals 5 and 7.
  • Page 27 RUGGEDCOM RSG2100PF Chapter 2 Installation Guide Installing Device Figure 9: DC and 48 VDC PoE Power Supply Figure 10: AC and 48 VDC PoE Power Supply Wiring Examples...
  • Page 28 Chapter 2 RUGGEDCOM RSG2100PF Installing Device Installation Guide Wiring Examples...
  • Page 29: Device Management

    Connecting to the Device The following describes the various methods for accessing the ROS-F console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS-F User Guide for the RUGGEDCOM RSG2100PF. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and ROS-F interfaces.
  • Page 30: Configuring The Device

    Chapter 3 RUGGEDCOM RSG2100PF Device Management Installation Guide Name Description Comment RJ45 Male Female Read to Send Ring Indicator The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected.
  • Page 31: Communication Ports

    Chapter 4 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RSG2100PF can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 12: Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2100PF chassis: •...
  • Page 32: Copper Ethernet Ports

    Section 4.1 Copper Ethernet Ports The RUGGEDCOM RSG2100PF supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 or Micro-D male connectors. The RJ45 and Micro-D connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 33 RUGGEDCOM RSG2100PF Chapter 4 Installation Guide Communication Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi-Directional Pair B+ Reserved (Do BI_DC+ Transmit Data+ Not Connect) or Bi-Directional Pair C+ Reserved (Do BI_DC- Receive Not Connect) Data- or Bi- Directional Pair C-...
  • Page 34: Poe Ports

    Section 4.2 PoE Ports The RUGGEDCOM RSG2100PF comes standard with two 10/100Base-TX Power over Ethernet (POE) ports powered by an external power supply. Each port complies with the IEEE 802.3af standard and features auto-sensing and automatic power off when cables are removed.
  • Page 35: Fiber Optic Ethernet Ports

    The RUGGEDCOM RSG2100PF features two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. The following SFP transceivers are compatible with the RUGGEDCOM RSG2100PF. For more information, including installation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog [https://support.industry.siemens.com/cs/ww/en/view/109482309].
  • Page 36: Gbic Optic Ethernet Ports

    To install a GBIC optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 37 IMPORTANT! Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2100PF. Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges (ESD). This can be accomplished by wearing an ESD-preventive wrist strap connected to either the chassis ground connector or a bare metal surface on the router/switch.
  • Page 38: Removing A Gbic Optical Port

    Chapter 4 RUGGEDCOM RSG2100PF Communication Ports Installation Guide Section 4.5.2 Removing a GBIC Optical Port To remove an GBIC optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before performing installing or removing components from the device.
  • Page 39: Technical Specifications

    Section 5.9, “Dimension Drawings” Section 5.1 Power Supply Specifications The RUGGEDCOM RSG2100PF can be equipped with the following power supplies: CAUTION! Electrical hazard – risk of power supply failure or damage to the device. Make sure power input to the device is within the specified input range. If power input is too high, damage to the power supply may occur.
  • Page 40: Poe Power Supply Specifications

    Chapter 5 RUGGEDCOM RSG2100PF Technical Specifications Installation Guide (T) denotes time-delay fuse. Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports. The HI power supply is the same power supply for both AC and DC.
  • Page 41: Copper Ethernet Port Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 42: Operating Environment

    -11.2 14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications...
  • Page 43: Mechanical Specifications

    RUGGEDCOM RSG2100PF Chapter 5 Installation Guide Technical Specifications Ambient Relative Humidity 5% to 95% Maximum Altitude 2000 m (6562 ft) Measured from a 30 cm (12 in) radius surrounding the center of the enclosure. Non-condensing Section 5.8 Mechanical Specifications Weight 5.2 kg (11.5 lbs)
  • Page 44 Chapter 5 RUGGEDCOM RSG2100PF Technical Specifications Installation Guide 438.15 Figure 24: Overall Dimensions Dimension Drawings...
  • Page 45 RUGGEDCOM RSG2100PF Chapter 5 Installation Guide Technical Specifications 479.29 461.01 11.68 21.08 32.64 4.57 Figure 25: Rack Mount Dimensions Dimension Drawings...
  • Page 46 Chapter 5 RUGGEDCOM RSG2100PF Technical Specifications Installation Guide 486.4 10.4 476.3 STATUS ALAR M DUPLE X POWER1 SPEE D POWER2 CONSO LE 57600-N-8-1 MODE 11.7 Figure 26: Panel and DIN Rail Mount Dimensions Dimension Drawings...
  • Page 47: Certification

    RUGGEDCOM RSG2100PF Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSG2100PF device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 48: European Union (Eu)

    Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 49: Ised

    Installation Guide Certification Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 This device was designed and manufactured using a certified ISO (International Organization for Standardization) quality program that adheres to the following standard: •...
  • Page 50: Emc And Environmental Type Tests

    Certification Installation Guide Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RSG2100PF has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 NOTE • If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance errors may occur but recovery is automatic.
  • Page 51 EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RSG2100PF meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 52 Chapter 6 RUGGEDCOM RSG2100PF Certification Installation Guide Description Test Levels 1 kV differential mode @ 1 MHz AC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz HV Impulse Signal Ports 5 kV (Fail-Safe Relay Output) DC Power Ports...