Siemens RUGGEDCOM RSG2300P Installation Manual
Siemens RUGGEDCOM RSG2300P Installation Manual

Siemens RUGGEDCOM RSG2300P Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2300P:

Advertisement

Quick Links

RUGGEDCOM RSG2300P
Installation Guide
05/2018
RC1047-EN-11
Preface
Introduction
Installing Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSG2300P

  • Page 1 Preface Introduction Installing Device RUGGEDCOM RSG2300P Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 05/2018 RC1047-EN-11...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RSG2300P Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario https://www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RSG2300P Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RSG2300P   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 Chapter 2 Installing Device ....................
  • Page 6   RUGGEDCOM RSG2300P Table of Contents Installation Guide 3.3  Fiber Optic Ethernet Ports ......................22 3.4  SFP Transceivers ......................... 23 3.5  GBIC Optic Ethernet Ports ......................24 3.5.1  Installing a GBIC Optical Port .................... 24 3.5.2  Removing a GBIC Optical Port ................... 25 Chapter 4 Technical Specifications ..................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG2300P. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9: Customer Support

    RUGGEDCOM RSG2300P   Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
  • Page 10   RUGGEDCOM RSG2300P Preface Installation Guide Customer Support...
  • Page 11: Introduction

    2 PoE ports, and offers modular flexibility of up to 6 additional Ethernet ports, including 10BaseFL/100BaseFX/1000BaseX fiber and 10/100/1000BaseTX copper port combinations. The RUGGEDCOM RSG2300P is highly versatile and can support multiple fiber types and connectors (ST, MTRJ, LC, SC) without loss of port density.
  • Page 12: Description

    Section 1.2 Description The RUGGEDCOM RSG2300P features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 13 RUGGEDCOM RSG2300P Chapter 1 Installation Guide Introduction Mode Color/State Description Duplex Green Full duplex mode Orange Half duplex mode No link detected Speed Green (Solid) 100 Mbps Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode for the port status indicator LEDs (i.e.
  • Page 14 Chapter 1 RUGGEDCOM RSG2300P Introduction Installation Guide Description...
  • Page 15: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: General Procedure

    Connect power to the device and ground the device to safety Earth. Connect the device to the network. Configure the device. Section 2.2 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2300P: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device.
  • Page 17: Gigabit Ethernet 1000Base-Tx Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 18: Mounting The Device To A Rack

    Section 2.4.1 Mounting the Device to a Rack The RUGGEDCOM RSG2300P can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 19: Mounting The Device On A Din Rail

    Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2300P can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 20: Mounting The Device To A Panel

    Section 2.4.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG2300P can be equipped with panelDIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 21: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROS. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for the RUGGEDCOM RSG2300P. The following shows the proper relay connections.
  • Page 22: Connecting Power

    1. Normally Open    2. Common    3. Normally Closed Section 2.6 Connecting Power The RUGGEDCOM RSG2300P supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RSG2300P can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power supply and PoE ports.
  • Page 23: Connecting Ac Or Dc Power

    RUGGEDCOM RSG2300P Chapter 2 Installation Guide Installing Device Section 2.6.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the field, remove the metal jumper.
  • Page 24: Connecting External Poe Power

    Install the terminal block cover. Section 2.6.2 Connecting External PoE Power The RUGGEDCOM RSG2300P supports up to four 10/100Base-TX Power-over-Ethernet (POE) Ports that require power from an external source. NOTE For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in).
  • Page 25: Wiring Examples

    RUGGEDCOM RSG2300P Chapter 2 Installation Guide Installing Device Connecting the External Power Supply To connect an external power supply for the PoE ports, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Only connect the external PoE power supply to the terminals 5 and 7.
  • Page 26: Connecting To The Device

    Connecting to the Device The following describes the various methods for accessing the ROS console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG2300P. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and ROS interfaces. The console port provides access to ROS's console and Web interfaces.
  • Page 27: Configuring The Device

    RUGGEDCOM RSG2300P Chapter 2 Installation Guide Installing Device IMPORTANT! The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting. Connection to the console port is made using an RJ45-to-DB9 console cable. The following is the pin-out for the...
  • Page 28 Chapter 2 RUGGEDCOM RSG2300P Installing Device Installation Guide Configuring the Device...
  • Page 29: Communication Ports

    Chapter 3 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RSG2300P can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 12: Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2300P chassis: •...
  • Page 30: Copper Ethernet Ports

    Section 3.1 Copper Ethernet Ports The RUGGEDCOM RSG2300P supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 male connectors. The RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 31: Poe Ports

    Ports can also be enabled/disabled and placed on a power schedule to conserve power. For more information, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG2300P. For information about connecting the external power supply, refer to Section 2.6.2, “Connecting External PoE...
  • Page 32: Fiber Optic Ethernet Ports

    Chapter 3 RUGGEDCOM RSG2300P Communication Ports Installation Guide State Description Yellow (Blinking) Transmitting/receiving No link detected Pin-Out The pin-out for the PoE ports is as follows: Description RX + and Power - RX - and Power - TX + and Power + Reserved (Do Not Connect) Figure 15: RJ45 Ethernet Port PoE Pin Configuration...
  • Page 33: Sfp Transceivers

    The RUGGEDCOM RSG2300P features two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. The following SFP transceivers are compatible with the RUGGEDCOM RSG2300P. For more information, including installation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog [https://support.industry.siemens.com/cs/ca/en/view/109482309].
  • Page 34: Gbic Optic Ethernet Ports

    To install a GBIC optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 35: Removing A Gbic Optical Port

    Communication Ports IMPORTANT! Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2300P. Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges (ESD). This can be accomplished by wearing an ESD-preventive wrist strap connected to either the chassis ground connector or a bare metal surface on the router/switch.
  • Page 36 Chapter 3 RUGGEDCOM RSG2300P Communication Ports Installation Guide CAUTION! Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before performing installing or removing components from the device. An electrostatic discharge (ESD) can cause serious damage to the component once it is outside the chassis.
  • Page 37: Technical Specifications

    Section 4.8, “Mechanical Specifications” Section 4.1 Power Supply Specifications The RUGGEDCOM RSG2300P can be equipped with the following power supplies: CAUTION! Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power input is above or below the specified input range.
  • Page 38: Poe Power Supply Specifications

    Chapter 4 RUGGEDCOM RSG2300P Technical Specifications Installation Guide The HI power supply is the same power supply for both AC and DC. Section 4.2 PoE Power Supply Specifications Input Range Maximum Power Power Supply Type Internal Fuse Rating Consumption Minimum Maximum...
  • Page 39: Copper Ethernet Port Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 40 All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
  • Page 41: Operating Environment

    All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
  • Page 42 Chapter 4 RUGGEDCOM RSG2300P Technical Specifications Installation Guide Mechanical Specifications...
  • Page 43: Dimension Drawings

    RUGGEDCOM RSG2300P Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. NOTE Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stated.
  • Page 44 Chapter 5 RUGGEDCOM RSG2300P Dimension Drawings Installation Guide 438.15 Figure 23: Overall Dimensions...
  • Page 45 RUGGEDCOM RSG2300P Chapter 5 Installation Guide Dimension Drawings 32.64 21.08 11.68 479.29 461.01 4.57 Figure 24: Rack Mount Dimensions...
  • Page 46 Chapter 5 RUGGEDCOM RSG2300P Dimension Drawings Installation Guide 486.4 476.3 10.4 11.7 Figure 25: Panel and DIN Rail Mount Dimensions...
  • Page 47: Certification

    RUGGEDCOM RSG2300P Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSG2300P device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 48: European Union (Eu)

    Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 49: Ised

    Chapter 6 Installation Guide Certification Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 ACMA This device meets the requirements of the following Australian Communications and Media Authority (ACMA) standards under certificate ABN 98 004 347 880: •...
  • Page 50: Other Approvals

    • IEC 61850-3 Communication Networks and Systems in Substations – Part 3: General Requirements Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RSG2300P has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 Test...
  • Page 51 EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RSG2300P meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 52 Chapter 6 RUGGEDCOM RSG2300P Certification Installation Guide Description Test Levels Fast Transient Signal Ports 4 kV @ 2.5 kHz DC Power Ports 4 kV AC Power Ports 4 kV Earth Ground Ports 4 kV Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common...

Table of Contents