HP StoreEver MSL3040 User's And Service Manual page 204

Tape libraries
Table of Contents

Advertisement

Event
Message text and description
code
2043
Wellness test failed because bottom
cover is missing.
2044
Wellness test failed because drive power
board failed.
2045
Wellness test failed because move
media test failed.
204
Event codes
Details and solution
1. Verify that both the top and bottom covers
are properly installed.
2. Verify that the module interconnect cables
are properly connected.
3. Verify that all modules are powered on.
Each module has two drive power boards,
which are located under the chassis fan. The
left drive power board provides power for the
upper three half-height tape drive bays in the
module. The right drive power board provides
power for the lower three half-height tape drive
bays in the module. See the event details to
determine which drive power board failed.
1. Ensure that the drive power boards are fully
seated in the module.
2. Reboot or power cycle the library.
1. Verify that at least one unloaded drive and
one data cartridge compatible with that
unloaded drive are installed in the library. If
no drives are unloaded or no compatible
cartridge is found, the test will fail and this
error event will be generated.
2. Unload all tape drives and then rerun the
test.
3. Check for obstructions between the robotic
assembly and magazines.
4. Ensure that the alignment mechanisms for
all modules above the bottom module are
engaged and locked.
5. Verified that the rack is level front to front
and back to back.
6. Verify that the robotics assembly is not stuck
in the lock mechanism. Move the robotics
assembly away from the locking mechanism
and enable the lock mechanism correctly.
Table Continued