HP StoreEver MSL3040 User's And Service Manual page 199

Tape libraries
Table of Contents

Advertisement

Event
Message text and description
code
2005
Robotic spooling cable failure
2006
Cable to spooling mechanism has failed.
2007
Move command failed due to spooling
mechanism failure
2008
Exchange cartridge failed due to
spooling mechanism failure
2009
Library test failed due to robotics
problem
2010
Library test failed due to spooling
mechanism defect
2011
A drive power board has failed. Because
of this failure, some drives might be
powered off.
2012
Multiple bottom covers detected.
2013
Multiple top covers detected.
Details and solution
Ensure that the spooling cable is fully seated in
the base module and correctly connected to the
robotic assembly.
Review the test requirements, address any
issues, and then retry the test.
Clear any obstructions from the bottom of
the library. For instructions, see .
Ensure that the spooling mechanism is fully
seated in the base module and installed
correctly with the robotic assembly.
Each module has two drive power boards,
which are located under the chassis fan. The
left drive power board provides power for the
upper three half-height tape drive bays in the
module. The right drive power board provides
power for the lower three half-height tape drive
bays in the module. See the event details to
determine which drive power board failed.
1. Ensure that the drive power boards are fully
seated in the module.
2. Reboot or power cycle the library.
Remove all bottom covers except for the bottom
module in the library.
Remove all top covers except for the top
module in the library.
Table Continued