HP StoreEver MSL3040 User's And Service Manual page 208

Tape libraries
Table of Contents

Advertisement

Event
Message text and description
code
2060
Chassis CPU maximum temperature
exceeded. Shutting down the system.
2061
Move failed pulling cartridge from drive.
2062
Move failed inserting cartridge into drive. Check for labels or cartridge misalignments that
2063
Move failed positioning picker in front of
drive.
2064
Library test failed with critical error.
2065
Library startup process failed because of
robotics initialization issue.
208
Event codes
Details and solution
Verify that the ambient air temperature is
within acceptable limits.
Verify that nothing is obstructing airflow from
the front or back of the library.
Check for labels or cartridge misalignments that
would prevent the cartridge from coming out of
the drive.
would prevent the cartridge from being inserted
into the drive.
Check for additional events that might
provide an indication of the reason for the
failure.
Check for obstructions in the vertical or
horizontal pathway of the robotics assembly,
such as a cartridge that is not seated
completely in a slot or a problem with the
robotic spooling cable that is impeding
progress.
Verify that the robotic assembly is level
within the module. If the module was
recently moved or the robotic assembly
replaced, the assembly could be out of
alignment.
1. Check for additional events that might
provide an indication of the reason for the
failure.
2. Verify that the minimum requirements are
met for the test and then retry the test.
3. To verify robotic movement, perform a slot-
to-slot or element-to-element test.
Check for obstructions, such as a cartridge
sticking out, in the vertical pathway of the
robotics assembly.
Check for objects in the bottom of the library
blocking the path of the robotic assembly.
Table Continued

Advertisement

Table of Contents
loading

Table of Contents