Event
Message and description
code
4083
Library not properly calibrated. Lack of
calibration might cause media movement
failures.
4084
Failed reading logged in hosts table.
4085
Too many retries of drive command needed
because of Unit Attention or Not Ready
condition.
226
Event codes
Details and solution
1. Verify that the library is running the most
recent firmware version.
2. Power cycle the library. The library
initiates the calibration operation during
power-on. If the calibration operation
does not begin during the power-on or
the error persists, initiate the auto
calibrate operation from the
Maintenance > Auto Calibration RMI
screen.
For more information about auto calibration,
see Calibrating the library on page 105.
NOTE:
The Auto Calibration routine can take up to
15 minutes per module. The library will be
offline to hosts while the routine is running.
1. Verify that the drive is powered on and is
communicating with the library.
2. Verify that the drive is running a firmware
version that is supported with the library
firmware version.
3. If this error persists, disable Secure
Manager for the entire library and then
re-enable Secure Manager.
1. Check for additional events that might
provide an indication of the reason for
the failure.
2. Check the data cartridge in the drive for
damage and wear.
3. Wait for drive operation to complete and
then retry the command.
Table Continued