Integrator's Reference Manual for Polycom HDX Systems
mute
Sets or gets the near or far site mute settings.
Syntax
mute <register|unregister>
mute near <get|on|off|toggle>
mute far get
Parameter
register
unregister
near
get
on
off
toggle
far
Feedback Examples
● mute register
returns
mute registered
● mute near on
returns
mute near on
● mute far get
returns
mute far off
Comments
In register mode, the system sends notification to the API session when the far or near site is muted or
unmuted.
Polycom, Inc.
Description
Registers to receive notification when the mute mode
changes.
Disables register mode.
Sets the command for the near site. Requires on, off,
toggle, or get.
Returns the current setting for the near or far site.
Mutes the near site (mute near on).
Unmutes the near site (mute near off).
If mute near mode is mute near on, this switches to
mute near off, and vice versa.
Returns the mute state of the far site system. Requires
the parameter get.
System Commands
353
Need help?
Do you have a question about the HDX 9006 and is the answer not in the manual?