Integrator's Reference Manual for Polycom HDX Systems
gatewayprefix
Sets or gets the gateway prefixes for the corresponding speeds.
Syntax
gatewayprefix get "valid speed"
gatewayprefix set "valid speed" ["value"]
Parameter
get
"valid speed"
set
"value"
Feedback Examples
● gatewayprefix set 168 90
returns
gatewayprefix 168 90
● gatewayprefix get 168
returns
gatewayprefix 168 90
Comments
Some gateways require a number to be prepended (prefix) to the gateway number. The prefix identifies
which gateway is used to dial a call at a particular data rate.
Polycom, Inc.
Description
When followed by the "valid speed" parameter,
returns the current value for this speed.
Valid speeds are: 56, 64, 2x56, 112, 2x64, 128, 168,
192, 224, 256, 280, 320, 336, 384, 392, 7x64, 8x56,
504, 512, 560, 576, 616, 640, 672, 704, 728, 768, 784,
832, 840, 16x56, 14x64, 952, 960, 1008, 1024, 1064,
1088, 1120, 1152, 1176, 1216, 1232, 1280, 1288, 24x56,
21x64, 1400, 1408, 1456, 1472, 1512, 1536, 1568,
1600, 1624, 1664, 1680, 1728, 1736, 32x56, 28x64,
1848, 1856, 1904, and 1920 kbps.
Sets the gateway prefix when followed by the "value"
parameter. To erase the current setting, omit "value".
Prefix (code) used for a particular call speed. Consult
your gateway instruction manual to determine which
codes are appropriate.