TE01: Installation and activation of loadable compile cycles
9.1 Loading compile cycles
9.1.2

Loading a compile cycle with HMI Advanced

Precondition
To transfer a compile cycle to the control, the following requirements must be met:
A storage medium (e.g. USB FlashDrive), which stores the compile cycle, is connected to the
PCU.
Execution
Perform the following operation to load a compile cycle from a USB FlashDrive in the NCK:
1. Insert the USB FlashDrive into the PCU 50/70.
2. Open the USB FlashDrive as the local drive:
Operating area switchover > Services > Data admin > Local USB
If the "Local USB" is displayed as disabled, it implies the USB FlashDrive was not
detected. Wait until HMI Advanced has detected the USB FlashDrive.
3. Select the compile cycle and copy it:
vertical "Copy" softkey
4. Go to the OEM directory of the NC card:
etc Key ">" > NC Card > Directory: "cc" or "Loadable Compile Cycles"
5. Add the compile cycle to the NC card's OEM directory:
Vertical "Add" softkey
6. Initiate an NCK reset.
9.1.3

Loading a compile cycle from an external computer with WinSCP3

Precondition
To transfer a compile cycle to the control, the following requirements must be met:
The external computer (programming device / PC) which the compile cycle is loaded onto
is linked to the PCU via a network (TCP / IP).
The program "WinSCP3" is installed on the external computer.
The host name or the IP address of the PCU is known.
The user name and the password to log onto the PCU are known.