TE1: Clearance control
11.6 Programming
11.6.7

Selection of the active sensor characteristic (CLC_SEL)

Syntax
CLC_SEL(
Characteristic number
Format: Integer
Range of values: 1, 2
CLC_SEL(...) is a procedure call and must therefore be programmed in a dedicated part
program block.
Characteristic number
without alarm.
Functionality
CLC_SEL can be used to switch between the sensor characteristics defined in the machine
data.
Characteristic 1:
-
-
Characteristic 2:
-
-
RESET response
Characteristic 1 becomes effective after a power on reset, NC RESET or end of program.
492
characteristic number
= 2 selects characteristic 2. Any other value selects characteristic 1
MD62510 $MC_CLC_SENSOR_VOLTAGE_TABLE_1 (coordinate voltage of
interpolation points sensor characteristic 1)
MD62511 $MC_CLC_SENSOR_VELO_TABLE_1 (coordinate velocity of interpolation
points sensor characteristic 1)
MD62512 $MC_CLC_SENSOR_VOLTAGE_TABLE_2 (coordinate voltage of
interpolation points sensor characteristic 2)
MD62513 $MC_CLC_SENSOR_VELO_TABLE_2 (coordinate velocity of interpolation
points sensor characteristic 2)
)