Siemens SINUMERIK 840D sl Function Manual page 494

Special functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

TE1: Clearance control
11.7 Function-specific display data
HMI Advanced
Proceed as follows to create and display the GUD variables in HMI Advanced.
1. Setting the password
Enter the password for protection level 1: (machine manufacturer).
2. Activate the "definitions" display.
Operating area switchover > Services > Data Selection
3. If no SGUD.DEF file is yet available:
Operating area switchover > Services > Data admin > New...
Name: SGUD
Type: Global data/system
Confirm with OK.
This opens the file in the editor.
1. Edit the GUD variable definitions
DEF CHAN REAL CLC_DISTANCE[3] ; Array of real, 3 elements
DEF CHAN REAL CLC_VOLTAGE[3] ; Array of real, 3 elements
M30
2. Save the file and close the editor.
3. Activate the SGUD.DEF file.
The GUD variables for clearance control are now displayed under:
Operating area switchover > Parameters > User data > Channel user data
HMI Embedded
Proceed as follows to create and display the GUD variables in HMI Embedded.
1. Setting the password
Enter the password for protection level 1: (machine manufacturer).
2. If no SGUD.DEF file is yet available:
Operating area switchover > Services > Data admin > Programs/Data: Set cursor to
definitions > New...
Name: SGUD
Type: DEF
Confirm with OK.
This opens the file in the editor.
1. Edit the GUD variable definitions
DEF CHAN REAL CLC_DISTANCE[3] ; Array of real, 3 elements
DEF CHAN REAL CLC_VOLTAGE[3] ; Array of real, 3 elements
M30
2. Save the file and close the editor.
3. Activate the SGUD.DEF file.
The GUD variables for clearance control are now displayed under:
Operating area switchover > Parameters > User data > Channel spec. user data
494
Function Manual, 09/2011, 6FC5397-2BP40-2BA0
Special Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents