Creating Alarm Texts With Hmi Advanced - Siemens SINUMERIK 840D sl Function Manual

Special functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

9.6.2

Creating alarm texts with HMI Advanced

The following alarms should be added to the alarm texts of the technology functions:
075999 0 0 "Channel %1 Sentence %2 Call parameter is invalid"
Proceed as follows
1. Copy the "mbdde.ini" file from the "F:\mmc2" directory to the "F:\oem" directory.
2. Add the following two lines in the "mbdde.ini" file:
[TextFiles]
UserCZYK=F:\oem\alc_
3. Create the language-dependent "alc_XX.com" text files in the "F:\oem" directory, e.g.:
"alc_GR.com" for German
"alc_UK.com" for English
4. Insert the new alarm text in the language-dependent text files, e.g.:
075999 0 0 "Channel %1 Sentence %2 Call parameter is invalid"
in the text file in German.
5.Restart HMI Advanced.
For more information about creating alarm texts with HMI Advanced, please refer to:
References:
/IAM/ SINUMERIK 840D sl/840Di sl/840D/840Di Startup CNC Part 2 (HMI); Startup HMI
Advanced (IM4), Chapter: Creating user alarm texts
Note
HMI reinstallation
Retain the added alarm texts in the text files of the F:\oem even after a reinstallation of HMI.