Execution
Perform the following steps to load a compile cycle from a USB-FlashDrive, for example:
1. Insert the USB-FlashDrive in the USB interface on the front of the operator panel.
2. At the user interface, change into the "System data" area:
Horizontal softkey bar: "Operating area switchover" > "Commissioning" > "System data"
3. Open the USB-FlashDrive: Directory "USB" (keyboard: "Enter" key).
4. Select the compile cycle and copy it:
Vertical softkey bar: "Copy"
5. Within the "System data" area, switch into the directory "NC data" > "Compile cycles" and
insert the compile cycle there:
Vertical softkey bar: "Insert"
6. Initiate an NCK reset to activate the compile cycle:
Horizontal softkey bar: "Operating area switchover" > "Commissioning" > "Machine data"
Vertical softkey bar: "Reset (po)"
13.1.2
Loading a compile cycle with HMI Advanced
Precondition
To transfer a compile cycle to the control, the following requirements must be met:
A storage medium (e.g. USB FlashDrive), which stores the compile cycle, is connected to the
PCU.
Execution
Perform the following operation to load a compile cycle from a USB FlashDrive to the NC:
1. Insert the USB FlashDrive into the PCU 50/70.
2. Open the USB FlashDrive as the local drive:
Operating area switchover > Services > Data admin > Local USB
If the "Local USB" is displayed as disabled, it implies the USB FlashDrive was not detected.
Wait until HMI Advanced has detected the USB FlashDrive.
3. Select the compile cycle and copy it:
vertical "Copy" softkey
4. Go to the OEM directory of the NC card:
ETC key (">") > "NC card" > Directory: "cc" or "Loadable Compile Cycles"
5. Add the compile cycle to the NC card's OEM directory:
Vertical "Add" softkey
6. Initiate an NCK reset.
Special functions
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
TE01: Installation and activation of loadable compile cycles
13.1 Loading compile cycles
551