3. Physical installation
Ensure good condition of the lamp house blower. Keep the blower inlet clean for unrestricted air flow.
To ensure maximum lamp life, operate the lamp house blower and the exhaust system for at least ten minutes
after extinguishing the lamp.
Optional electrical connection of the fan to the projector
The exhaust fan may electrically be connected with the projector. When that is done, the blower starts working when the lamp is
switched on and stops working after the cool period is completed.
The power socket is located next to exhaust output and may only be used to connect the external exhaust fan. No connection with
other devices is allowed.
The exhaust outlet delivers maximum 3A, 200-240V at 50-60Hz.
The external fan power cord shall be not less than 0.75 mm² or AWG 18.
Image 3-6
Fan power connection
28
R5905963 PROMETHEUS SERIES 09/03/2015