Edge-Core ECS4120-28F Reference Manual page 774

28/52-port layer 2+ gigabit ethernet switch
Hide thumbs Also See for ECS4120-28F:
Table of Contents

Advertisement

Chapter 26
| CFM Commands
Table 157: CFM Commands
Command
ma index name-format
ethernet cfm mep
ethernet cfm port-enable
clear ethernet cfm ais mpid
show ethernet cfm
configuration
show ethernet cfm md
show ethernet cfm ma
show ethernet cfm
maintenance-points local
show ethernet cfm
maintenance-points local
detail mep
show ethernet cfm
maintenance-points
remote detail
Continuity Check Operations
ethernet cfm cc ma interval
ethernet cfm cc enable
snmp-server enable traps
ethernet cfm cc
mep archive-hold-time
clear ethernet cfm
maintenance-points
remote
clear ethernet cfm errors
show ethernet cfm errors
Cross Check Operations
ethernet cfm mep
crosscheck start-delay
snmp-server enable traps
ethernet cfm crosscheck
mep crosscheck mpid
(Continued)
Function
Specifies the name format for the maintenance association
as IEEE 802.1ag character based, or ITU-T SG13/SG15 Y.1731
defined ICC-based format
Sets an interface as a domain boundary, defines it as a
maintenance end point (MEP), and sets direction of the
MEP in regard to sending and receiving CFM messages
Enables CFM processing on an interface
Clears AIS defect information for the specified MEP
Displays CFM configuration settings, including global
settings, SNMP traps, and interface settings
Displays configured maintenance domains
Displays configured maintenance associations
Displays maintenance points configured on this device
Displays detailed CFM information about a specified local
MEP in the continuity check database
Displays detailed CFM information about a specified
remote MEP in the continuity check database
Sets the transmission delay between continuity check
messages
Enables transmission of continuity check messages within
a specified maintenance association
Enables SNMP traps for CFM continuity check events
Sets the time that data from a missing MEP is kept in the
continuity check database before being purged
Clears the contents of the continuity check database
Clears continuity check errors logged for the specified
maintenance domain and maintenance level
Displays CFM continuity check errors logged on this device PE
Sets the maximum delay that a device waits for remote
MEPs to come up before starting the cross-check operation
Enables SNMP traps for CFM continuity check events, in
relation to the cross-check operations between statically
configured MEPs and those learned via continuity check
messages
Statically defines a remote MEP in a maintenance
association
– 774 –
Mode
CFM
IC
IC
PE
PE
PE
PE
PE
PE
PE
GC
GC
GC
CFM
PE
PE
GC
GC
CFM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs4120-28f-iEcs4120-28tEcs4120-28pEcs4120-52t

Table of Contents