Sntp Poll - Edge-Core ECS4120-28F Reference Manual

28/52-port layer 2+ gigabit ethernet switch
Hide thumbs Also See for ECS4120-28F:
Table of Contents

Advertisement

Chapter 4
| System Management Commands
Time

sntp poll

Example
Console(config)#sntp server 10.1.0.19
Console(config)#sntp poll 60
Console(config)#sntp client
Console(config)#end
Console#show sntp
Current Time
: Mar 12 02:33:00 2015
Poll Interval
: 60 seconds
Current Mode
: Unicast
SNTP Status
: Enabled
SNTP Server
: 10.1.0.19
Current Server : 137.92.140.80
Console#
Related Commands
sntp server (157)
sntp poll (156)
show sntp (157)
This command sets the interval between sending time requests when the switch is
set to SNTP client mode. Use the no form to restore to the default.
Syntax
sntp poll seconds
no sntp poll
seconds - Interval between time requests. (Range: 16-16384 seconds)
Default Setting
16 seconds
Command Mode
Global Configuration
Example
Console(config)#sntp poll 60
Console#
Related Commands
sntp client (155)
– 156 –