Sflow Owner - Edge-Core ECS4120-28F Reference Manual

28/52-port layer 2+ gigabit ethernet switch
Hide thumbs Also See for ECS4120-28F:
Table of Contents

Advertisement

Chapter 7
| Flow Sampling Commands

sflow owner

This command creates an sFlow collector on the switch. Use the no form to remove
the sFlow receiver.
Syntax
sflow owner owner-name timeout timeout-value
[destination {ipv4-address | ipv6-address}
[max-datagram-size max-datagram-size] [port destination-udp-port]
[version {v4 | v5]] [port destination-udp-port]
no sflow owner owner-name
owner-name - Name of the collector. (Range: 1-30 alphanumeric characters)
timeout-value - The length of time the sFlow interface is available to send
samples to a receiver, after which the owner and associated polling and
sampling data source instances are removed from the configuration.
(Range: 30-10000000 seconds)
ipv4-address - IPv4 address of the sFlow collector. Valid IPv4 addresses
consist of four decimal numbers, 0 to 255, separated by periods.
ipv6-address - IPv6 address of the sFlow collector. A full IPv6 address
including the network prefix and host address bits. An IPv6 address consists
of 8 colon-separated 16-bit hexadecimal values. One double colon may be
used to indicate the appropriate number of zeros required to fill the
undefined fields.
destination-udp-port - The UDP port on which the collector is listening for
sFlow streams. (Range: 1-65535)
max-datagram-size - The maximum size of the sFlow datagram payload.
(Range: 200-1500 bytes)
version {v4 | v5} - Sends either v4 or v5 sFlow datagrams to the receiver.
Default Setting
No owner is configured
UDP Port: 6343
Version: v4
Maximum Datagram Size: 1400 bytes
Command Mode
Privileged Exec
Command Usage
Use the sflow owner command to create an owner instance of an sFlow
collector. If the socket port, maximum datagram size, and datagram version are
not specified, then the default values are used.
Once an owner is created, the sflow owner command can again be used to
modify the owner's port number. All other parameter values for the owner will
be retained if the port is modified.