Novajet PROe Series Service Manual
5. Slightly loosen the screws located on the back of the Y-arm
6. While lifting up the measuring tip of the micrometer, slide the
7. Move the left end of the stabilizer bracket until a reading of
62
Maintenance
Figure 3-17. Test Cartridge Installed.
that secures the stabilizer to the Y-arm.
Damage may occur to the micrometer
gauge if the Carrier is moved without
lifting up on the measuring tip. This
action could also take the micrometer
out of alignment and foul the results of
the alignment.
Carrier to the left side of the stabilizer. Position it as close to
the screw as possible and drop the measuring tip onto the
platen. Do this a couple of times to ensure an accurate
reading.
0.075" +/- 0.003" is observed. Read only the RED numbers on
the micrometer gauge.