Deadband Alignment - ENCAD 60e Service Manual

Novajet proe series color inkjet printer
Table of Contents

Advertisement

Deadband Alignment

Deadband calibration compensates for minute differences created
when bidirectional printing is used. Unidirectional printing is not
affected by deadband. There are four types of deadband tests:
4. When the plot is complete, select "Cyan Vertical" at the Color
Calib Menu. This brings up the options menu for the cyan
vertical adjustment as shown in Figure 3-21.
Figure 3-21. Cyan Vertical Options Menu.
5. Observe the plot and using either "Prev Option" or "Next
Option", rotate through the selections until the one that best
aligns the cyan color on the plot is selected. Press "Ok" to
accept the selection and return to the Color Calib Menu.
6. Continue until all six calibrations on the Color Calib Menu
have been accomplished.
slow deadband
fast deadband
fast deadband; vertical lines (all)
fast deadband; vertical lines (one).
Figure 3-22. Deadband Slow/Fast.