Modbus TCP On-Board Communications
Process Data
The process data fields are used to control the drive (e.g.,
Run, Stop, Reference, Fault Reset) and to quickly read actual
values (e.g., Output frequency, Output current, Fault code).
The fields are structured as follows.

Table 49. Process Data Slave R Master (max. 22 bytes)

ID
Modbus Register
Group
2101
32101, 42101
FB Status Word
2102
32102, 42102
FB General Status Word
2103
32103, 42103
FB Actual Speed
2104
32104, 42104
FB Process Data Out 1
2105
32105, 42105
FB Process Data Out 2
2106
32106, 42106
FB Process Data Out 3
2107
32107, 42107
FB Process Data Out 4
2108
32108, 42108
FB Process Data Out 5
2109
32109, 42109
FB Process Data Out 6
2110
32110, 42110
FB Process Data Out 7
2111
32111, 42111
FB Process Data Out 8

Table 50. Process Data Master R Slave (max. 22 bytes)

ID
Modbus Register
Group
2001
32001, 42001
FB Control Word
2002
32002, 42002
FB General Control Word
2003
32003, 42003
FB Speed Reference
2004
32004, 42004
FB Process Data In 1
2005
32005, 42005
FB Process Data In 2
2006
32006, 42006
FB Process Data In 3
2007
32007, 42007
FB Process Data In 4
2008
32008, 42008
FB Process Data In 5
2009
32009, 42009
FB Process Data In 6
2010
32010, 42010
FB Process Data In 7
2011
32011, 42011
FB Process Data In 8
The use of process data depends on the application. In a
typical situation, the device is started and stopped with the
ControlWord (CW) written by the Master and the Rotating
speed is set with Reference (REF). With PD1–PD8 the device
can be given other reference values (e.g., Torque reference).
With the StatusWord (SW) read by the Master, the status of
the device can be seen. Actual Value (ACT) and PD1–PD8
show the other actual values.
26
PowerXL DG1 Series VFD MN040010EN—May 2014 www.eaton.com
Process Data In
This register range is reserved for the control of the VFD.
Process Data In is located in range ID 2001–2099. The
registers are updated every 10 ms. See table below.

Table 51. Fieldbus Basic Input Table

ID
Modbus Register
Range/Type
2001
32001, 42001
Binary coded
2002
32002, 42002
Binary coded
2003
32003, 42003
0–100.00%
2004
32004, 42004
2005
32005, 42005
2006
32006, 42006
2007
32007, 42007
2008
32008, 42008
2009
32009, 42009
2010
32010, 42010
2011
32011, 42011
Control Word
PowerXL DG1 drive uses 16 bits as shown below. These bits
Range/Type
are application specific.
Binary coded

Table 52. PowerXL DG1 Drive 16 Bits

Binary coded
15 14 13 12 11 10
0–100.00% Hz
1
1
Integer 16
Notes
Integer 16
1
Not for use.
Integer 16
2
Net Ref.
3
Net Cntrl.
Integer 16
Integer 16

Table 53. Speed Reference

Integer 16
15
14 13 12 11 10
Integer 16
MSB — — — — — — — — — — — — — — LSB
Integer 16
This is the Reference 1 to the VFD. Used normally as Speed
reference.
Process Data In 1 to 8
Process Data In values 1 to 8 can be used in applications for
various purposes.
Group
FB Control Word
FB General Control Word
FB Speed Reference
FB Process Data In 1
FB Process Data In 2
FB Process Data In 3
FB Process Data In 4
FB Process Data In 5
FB Process Data In 6
FB Process Data In 7
FB Process Data In 8
9
8
7
6
BYS
1
1
1
1
2
3
1
9
8
7
Range/Type
Binary coded
Binary coded
0–100.00%
Integer 16
Integer 16
Integer 16
Integer 16
Integer 16
Integer 16
Integer 16
Integer 16
5
4
3
2
1
0
F_RST DIR RUN
1
1
1
6
5
4
3
2
1
0