9000X AF Drives User Manual
Fault Type
Fault Code
Fault Time
Data Record
5-8
Range: A, F, AR, FT
Fault Type
There are four different types of faults. These faults and their definitions are given in
Table 5-4.

Table 5-4: Fault Types

Fault
Type
Fault Name
A
Alarm
F
Fault
AR
Auto-Restart
Fault
FT
Fault Trip
Range: 1 – 54
Fault codes indicate the cause of the fault. A list of fault codes, their descriptions,
and possible solutions can be found in Appendix B — Fault and Warning Codes.
Range: T.1 – T.13
In this menu, important data recorded at the time the fault is available. This feature
is intended to help the user or the service person to determine the cause of fault.
Table 5-5 indicates the information that is recorded.

Table 5-5: Fault Time Data

Data
Units
T.1
D
T.2
hh:mm:ss
(d)
T.3
Hz
hh:mm:ss
T.4
A
T.5
V
T.6
%
T.7
%
T.8
V
T.9
°C
T.10
T.11
T.12
T.13
Real time record.
If real time is set, T.1 and T.2 will appear as follows:
T.1
yyyy-mm-dd
Counted operation days (Fault 43: Additional code)
T.2
hh:mm:ss.sss
Counted operation hours (Fault 43: Counted operation days)
For more information visit: www.eaton.com
Description
This type of fault is a sign of an unusual operating
condition. It does not cause the drive to stop, nor does it
require any special actions. The "A fault" remains in the
display for about 30 seconds.
An "F fault" is a kind of fault that makes the drive stop.
Actions need to be taken in order to restart the drive.
If an "AR fault" occurs the drive will also stop
immediately. The fault is reset automatically and the drive
tries to restart the motor. If the restart is not successful, a
fault trip (FT) occurs.
If the drive is unable to restart the motor after an AR fault,
an FT fault occurs. The effect of the "FT fault" is the same
as that of the F fault — the drive is stopped.
Description
Counted operation days (Fault 43: Additional code)
Counted operation hours
(Fault 43: Counted operation days)
Output frequency
(Fault 43: Counted operation hours)
Motor current
Motor voltage
Motor power
Motor torque
DC bus voltage
Unit temperature
Run status
Direction
Warnings
Zero speed
June 2009
MN04001004E