User Manual Roth EnergyLogic Touchline/Wireless
Parameter descriptions
Parameter
P-42
IR
P-43
IR
88
Description
Set floor temperature correction of wireless room thermostat with integrated IR-
sensor.
●
Factory settings: Option "0"
●
Options:
–
0, standard setting: suitable for wood floors
–
1, average compensation: suitable for plastic floorings
–
2, high compensation: suitable for ceramic floors
NOTE
●
The specified settings apply at a room temperature of 22 °C.
●
For dark floorings or if the room temperature is at approx. 25 °C, you need to
switch up the compensation factor one level for all floors except for ceramic
floors.
●
No obstacles such as carpets, floorings or furniture must be placed in the meas-
uring range of the IR sensor.
●
Glossy floorings, e.g. due to sun irradiation, may cause measuring errors at the
IR sensor.
Operation
►
Press sensor button
►
Press sensor button
►
Select one of the following options:
–
Press sensor button
next parameter P-43.
–
Press sensor button
lected parameter.
Set maximum floor temperature of wireless room thermostat with integrated IR-
sensor.
This parameter avoids that the floor temperature exceeds a maximum temperature
level.
ATTENTION
This function is not designed as a safety limiter. Therefore any liability for damages
to the floor construction or plant components is expressly excluded. If a safety tem-
perature limiter function is required then this has to be provided by an external
hardwired safety temperature limiter (STB).
●
Factory settings: 35 °C
●
Setting range: 26...35 °C
●
Increment: 1 K
Operation
►
Press sensor button
►
Press sensor button
►
Select one of the following options:
–
Press sensor button
next parameter P-44.
–
Press sensor button
lected parameter.
. The display shows 0.
or
, to select option 1 or 2.
, to save the changed settings. The display shows the
, to interrupt the procedure. The display shows the se-
. The display shows 35.
or
, to change the value.
, to save the changed settings. The display shows the
, to interrupt the procedure. The display shows the se-
P100011294 E