180 Actual signals and parameters
All parameters
No.
Name/Value
DI2(INV)
DI3(INV)
DI4(INV)
DI5(INV)
1609 START
ENABLE 2
1610 DISPLAY
ALARMS
NO
YES
1611 PARAMETER
VIEW
FLASHDROP
SHORT VIEW
LONG VIEW
18 FREQ IN & TRAN
OUT
1801 FREQ INPUT
MIN
0...10000 Hz
1802 FREQ INPUT
MAX
0...10000 Hz
1803 FILTER FREQ
IN
0.0...10.0 s
1804 TO MODE
DIGITAL
FREQUENCY
1805 DO SIGNAL
1806 DO ON DELAY Defines the operation delay for digital output DO.
0.0...3600.0 s
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
Selects the source for the Start Enable 2 signal. See
parameter
START ENABLE 1.
1608
See parameter
1608
Activates/deactivates alarms OVERCURRENT (2001),
OVERVOLTAGE (2002), UNDERVOLTAGE (2003) and
DEVICE OVERTEMP (2009). For more information see
chapter
Fault tracing
Alarms are inactive.
Alarms are active.
Selects the parameter view, ie which parameters are shown
on the control panel.
Shows the FlashDrop parameter list. Does not include the
short parameter list. Parameters which are hidden by the
FlashDrop device are not visible.
FlashDrop parameter values are activated by setting
parameter
APPLIC MACRO to 31 (LOAD FD SET).
9902
Shows only a subset of all signals and parameters. See
section
Actual signals in the short parameter view
and
152
Parameters in the short parameter view
152.
Shows all signals (section
and parameters (this table, starting on page 161).
Frequency input and transistor output signal processing.
Defines the minimum input value when DI5 is used as a
frequency input. See section
Minimum frequency
Defines the maximum input value when DI5 is used as a
frequency input. See section
Maximum frequency
Defines the filter time constant for frequency input, ie the
time within 63% of a step change is reached. See section
on page 123.
Frequency input
Filter time constant
Selects the operation mode for the transistor output TO.
See section
Transistor output
Transistor output is used as a digital output DO.
Transistor output is used as a frequency output FO.
Selects a drive status indicated through digital output DO.
See parameter
1401
Delay time
START ENABLE 1.
on page 287.
All actual signals
Frequency input
Frequency input
on page 124.
RELAY OUTPUT 1.
Def/FbEq
-2
-3
-4
-5
NOT SEL
NO
0
1
SHORT
VIEW
1
2
on page
on page
on page 154)
3
0 Hz
on page 123.
1 = 1 Hz
1000 Hz
on page 123.
1 = 1 Hz
0.1 s
1 = 0.1 s
DIGITAL
0
1
FAULT(-1)
0.0 s
1 = 0.1 s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents