User Macros - ABB ACS310 User Manual

Hide thumbs Also See for ACS310:
Table of Contents

Advertisement

110 Application macros

User macros

In addition to the standard application macros, it is possible to create two user
macros. The user macro allows the user to save the parameter settings, including
group
99 START-UP
time. The panel reference is also saved if the macro is saved and loaded in local
control. The remote control setting is saved into the user macro, but the local control
setting is not.
The steps below show how to create and recall User macro 1. The procedure for the
User macro 2 is identical, only the parameter
To create User macro 1:
• Adjust the parameters.
• Save the parameter settings to the permanent memory by changing parameter
to -1 (USER S1 SAVE).
9902
SAVE
• Press
(Assistant Control Panel) or
To recall User macro 1:
• Change parameter
SAVE
• Press
(Assistant Control Panel) or
The user macro can also be switched through digital inputs (see parameter 1605).
Note: User macro load restores the parameter settings, including group
DATA. Check that the settings correspond to the motor used.
UP
Hint: The user can for example switch the drive between two motors without having
to adjust the motor parameters every time the motor is changed. The user needs only
to adjust the settings once for each motor and then to save the data as two user
macros. When the motor is changed, only the corresponding user macro needs to be
loaded, and the drive is ready to operate.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
DATA, into the permanent memory and recall the data at a later
to 0 (USER S1 LOAD).
9902
values are different.
9902
MENU
ENTER
(Basic Control Panel).
MENU
ENTER
(Basic Control Panel) to load.
99 START-

Hide quick links:

Advertisement

Table of Contents
loading