34 PANEL DISPLAY Selection of actual signals to be displayed on the panel
3401 SIGNAL1
PARAM
0, 101...178
3402 SIGNAL1 MIN
x...x
3403 SIGNAL1 MAX Defines the maximum value for the signal selected by
x...x
3404 OUTPUT1 DSP
FORM
+/-0
+/-0.0
+/-0.00
+/-0.000
+0
+0.0
+0.00
+0.000
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
Selects the first signal to be displayed on the control panel
in display mode.
Assistant panel
LOC
0137
0138
0139
Parameter index in group
SPEED. If value is set to 0, no signal is selected.
0102
Defines the minimum value for the signal selected by
parameter
SIGNAL1 PARAM.
3401
Display
value
3407
3406
Note: Parameter is not effective if parameter
OUTPUT1 DSP FORM setting is DIRECT.
Setting range depends on parameter
parameter
SIGNAL1 PARAM. See the figure for
3401
parameter
SIGNAL1 MIN.
3402
Note: Parameter is not effective if parameter
OUTPUT1 DSP FORM setting is DIRECT.
Setting range depends on parameter
Defines the format for the displayed signal (selected by
parameter
SIGNAL1 PARAM).
3401
Signed/Unsigned value. Unit is selected by parameter
OUTPUT 1 UNIT.
Example: PI (3.14159)
3404 value
+/-0
+/-0.0
+/-0.00
+/-0.000
+0
+0.0
+0.00
+0.000
Actual signals and parameters 203
3404 3405
15.0Hz
15 0 Hz
.
3 7 A
.
17 3 %
.
00:00
DIR
MENU
01 OPERATING
3402
3403
3401
3401
Display
+ 3
-32768...+32767
+ 3.1
+ 3.14
+ 3.142
3
3.1
3.14
3.142
Def/FbEq
103
DATA. Eg 102 =
1 = 1
-
Source
value
3404
setting.
-
-
3404
setting.
-
DIRECT
0
3405
1
2
Range
3
4
5
6
0...65535
7

Hide quick links: