No.
Name/Value
9907 MOTOR NOM
FREQ
10.0...500.0 Hz Frequency
9908 MOTOR NOM
SPEED
50...18000 rpm Speed
9909 MOTOR NOM
POWER
0.2...3.0 · P
kW Power
N
9914 PHASE
INVERSION
NO
YES
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
Defines the nominal motor frequency, ie the frequency at
which the output voltage equals the motor nominal voltage:
Field weakening point = Nom. frequency · Supply voltage /
Motor nom. voltage
Defines the nominal motor speed. Must be equal to the
value on the motor rating plate.
Defines the nominal motor power. Must equal the value on
the motor rating plate.
Inverts two phases in the motor cable. This changes the
direction of the motor rotation without having to exchange
the positions of two motor cable phase conductors at the
drive output terminals or at the motor connection box.
Phases not inverted
Phases inverted
Actual signals and parameters 263
Def/FbEq
E: 50.0 Hz
U: 60.0 Hz
1 = 0.1 Hz
Type
dependent
1 = 1 rpm
P
N
1 = 0.1
kW/hp
NO
0
1