Type Designation Label - ABB ACS310 User Manual

Hide thumbs Also See for ACS310:
Table of Contents

Advertisement

26 Operation principle and hardware description

Type designation label

The type designation label is attached to the left side of the drive. An example label
and explanation of the label contents are shown below.
2
IP20 / UL Open type
4 kW (5 HP)
U1 3~380...480 V
3
I1
15.0 A
f1
48...63 Hz
U2
3~0...U1 V
I2
9.7 A
f2
0...500 Hz
1 Type designation, see section
2 Degree of protection by enclosure (IP and UL/NEMA)
3 Nominal ratings, see section
4 Serial number of format MYYWWRXXXX, where
M:
Manufacturer
YY:
08, 09, 10, ..., for 2008, 2009, 2010, ...
WW:
01, 02, 03, ... for week 1, week 2, week 3, ...
R:
A, B, C, ... for product revision number
XXXX:
Integer starting every week from 0001
5 ABB MRP code of the drive
6 CE marking and C-Tick, C-UL US and RoHS marks (the label of your drive shows the valid
markings)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
ACS310-03E-09A7-4
lllllllllllllllllllllllllllllllllllllll
S/N MYYWWRXXXX
llllllllllllllllllllllllllllllllllllllll
3AUA0000039632
RoHS
Type designation key
on page 308.
Ratings
1
4
5
6
on page
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents