All Parameters; Start/Stop/Dir - ABB ACS310 User Manual

Hide thumbs Also See for ACS310:
Table of Contents

Advertisement

All parameters

All parameters
No.
Name/Value
10 START/STOP/DIR The sources for external start, stop and direction control
1001 EXT1
COMMANDS
NOT SEL
DI1
DI1,2
DI1P,2P
DI1P,2P,3
DI1P,2P,3P
KEYPAD
DI1F,2R
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
Defines the connections and the source for the start, stop
and direction commands for external control location 1
(EXT1).
No start, stop and direction command source
Start and stop through digital input DI1. 0 = stop, 1 = start.
Direction is fixed according to parameter
(setting REQUEST = FORWARD).
Start and stop through digital input DI1. 0 = stop, 1 = start.
Direction through digital input DI2. 0 = forward, 1 = reverse.
To control direction, parameter
must be REQUEST.
Pulse start through digital input DI1. 0 -> 1: Start. (In order to
start the drive, digital input DI2 must be activated prior to the
pulse fed to DI1.)
Pulse stop through digital input DI2. 1 -> 0: Stop. Direction
of rotation is fixed according to parameter
(setting REQUEST = FORWARD).
Note: When the stop input (DI2) is deactivated (no input),
the control panel start and stop buttons are disabled.
Pulse start through digital input DI1. 0 -> 1: Start. (In order to
start the drive, digital input DI2 must be activated prior to the
pulse fed to DI1.)
Pulse stop through digital input DI2. 1 -> 0: Stop. Direction
through digital input DI3. 0 = forward, 1 = reverse. To control
direction, parameter
REQUEST.
Note: When the stop input (DI2) is deactivated (no input),
the control panel start and stop buttons are disabled.
Pulse start forward through digital input DI1. 0 -> 1: Start
forward. Pulse start reverse through digital input DI2. 0 -> 1:
Start reverse. (In order to start the drive, digital input DI3
must be activated prior to the pulse fed to DI1/DI2). Pulse
stop through digital input DI3. 1 -> 0: Stop. To control the
direction, parameter
REQUEST.
Note: When the stop input (DI3) is deactivated (no input),
the control panel start and stop buttons are disabled.
Start, stop and direction commands through control panel
when EXT1 is active. To control the direction, parameter
DIRECTION setting must be REQUEST.
1003
Start, stop and direction commands through digital inputs
DI1 and DI2.
DI1
DI2
Operation
0
0
Stop
1
0
Start forward
0
1
Start reverse
1
1
Stop
Parameter
DIRECTION setting must be REQUEST.
1003
Actual signals and parameters 161
1003
DIRECTION setting
1003
DIRECTION setting must be
1003
DIRECTION setting must be
1003
Def/FbEq
DI1,2
0
1
DIRECTION
2
3
DIRECTION
1003
4
5
8
9