Measurement Procedure For Q-Level - Leica LS10 User Manual

Digital level
Hide thumbs Also See for LS10:
Table of Contents

Advertisement

7.2.2
Measurement
Procedure
Starting Screen
(First Backsight)
LS10/LS15, Programs

Measurement Procedure for Q-Level

Step
Description
The first screen allows you to measure the first backsight, which is the
starting point of the line.
1.
Enter the height of the starting point manually or search for an already stored
fixpoint or adjusted point in the current job.
2.
Measure the first backsight: Aim at the staff and press the trigger key.
Depending on the setting of the trigger key, the measurement is executed
with or without storing the measured values.
3.
After storing the measurement of the first backsight, the foresight screen is
displayed. Before measuring a foresight, you can measure intermediate
points or set out heights, height differences and distances.
You can define an individual point ID for the next point measured.
Refer to "Apply an Individual Point ID during measurements" (within
"7.1.3 Point ID & Incrementation").
4.
Measure the foresight. The procedure for aiming and measuring is the same
as described for the first backsight.
5.
After storing the measurement of the foresight, the next backsight screen is
displayed. You can continue to measure backsight and foresight points.
Before measuring the first backsight point, you can edit the following fields:
ID of the starting point (first backsight). Default value is "A1".
Backsight Pt
To search for fixpoints, enter a start point ID and confirm with the
ENTER key. For more details on pointsearch refer to "7.1.2
Pointsearch".
Backsight/Foresight: The current viewing direction
is highlighted in red.
If the trigger key is set to Dist or AF+Dist (only
LS15), press Rec (F2 softkey) to store the measure-
ment.
If the trigger key is set to Dist+Rec or AF+Dist+Rec
(only LS15), press Dist (F2 softkey) to take a meas-
urement without storing it; e.g. in order to verify the
correct distance of a foresight staff before the
actual measurement.
Focus
To automatically focus the telescope
(only LS15).
Rec
To save the measured values and
switch to the foresight screen.
If one or more fixpoints with this ID are
already stored in the current job, all available
fixpoints are displayed in the Points Found
screen. Select the desired fixpoint and press
Cont to return to the first backsight screen.
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: